Installation and Use
14 - GB
Technical data - room sensor (wireless version)
Power supply 2 x 1.5 V, LR03 (AAA) alkaline batteries
Alternatively
2 x 1.5 V, LR03 (AAA) 1200 mAh lithium bat-
teries
Battery life
2 years
Operating temperature
-0 to 40°C
Frequency band used
868.7-869.2 MHz
Maximum power in the band
< 10 mW
Receiver category
2
Reception range
100 m - 300 m in the open, depending on
the number of devices
Storage temperature
-10 to 70°C
Dimensions
93 x 88 x 24 mm
Insulation class
III
Protection rating
IP30 (when installed as specifi ed)
Temperature sensor
±1%
Technical data - room sensor (cabled version)
Power supply BridgeNet® BUS 8 to 24V
max / Limited
Power Source complies
Electrical uptake
6 mA
Operating temperature
-0 to 40°C
Storage temperature
-10 to 70°C
Dimensions
93 x 88 x 24 mm
Bus wire length and cross-sectional area
NOTE:
IN ORDER TO AVOID INTERFERENCE PROBLEMS, USE A
SHIELDED CABLE OR TWISTED PAIR CABLE.
max. 50 m - min. 0.5 mm²
Insulation class
III
Protection rating
IP30 (when installed as specifi ed)
Temperature sensor
±1%