User guide
Telephone Router Setting User Guide
Aristel Networks Pty Ltd 4x4 PABX/Router User Guide and Setting Tool Programming Rev 3.6
19
7.2 Main Basic Parameters
Call Pick-up Function Key (Default: 9)
This function key is for “Call Pick-up”. For example, there is a call,
and the Extension 11 is ringing. You can pick up the call from
extension 13 by dialing *9.
Ring Interval Time (Unit 100ms, Default 5 sec.)
Ring Time for Internal(Inner) Call (Default 30 sec.)
This is internal call ring time. Called extension stops ringing when this
time expires.
Call Transfer Time (Default: 20 Sec.)
This is call back time. If there is no reply from a transferred station the
system call back the extension that made the call transfer.
Outer(External) line Hold Time (External Line Hold Time) (Default: 3
min.)
Hot Line Delay Time (Default: 4 sec.)
Charge Delay Time (Default: 5 sec.)
Pause “p” Delay Time(Unit:100ms,Range: 200-2000ms)
This introduces an ability to insert a delay at the beginning of an insert
digit string or in the middle of an insert digit string. One “p” indicates
one unit delay. In some cases it can set “pp” or “ppp” in the target
number for 2 or 3 unit delays
Flash Time (Unit: 100ms, Range: 200-1500ms)
Caller ID Add Prefix Number (Default: 88)
This is the prefix for caller ID. For example, Extension 11 called
Extension 12 and therefore, the display on Extension will show 8811. If
it is transferred call the display shows 880011, indicating it is a
transferred call from 11.
Extension Number Digit Length (Default: 2, Range: 1-4)
Ring-Back on Call Transfer No Reply
Caller ID Add Prefix
Send Howler Tone
Transfer Talking Time. ( Another name could be Co to Co Call
Disconnect Time) When an incoming external call to an extension is call
forwarded to an external number, two trunk lines are made busy. They
won’t get released until this time expires. Default is set to 4 minutes (24 x
30 sec). Nearly 30 seconds before the forced disconnection of the trunk
lines both parties, still continuing their talk, can hear a “du du du “ warning
tone. At this time either party dialing “*” in 5 seconds can extend the
disconnect timer. By dialing “#” before ending their conversation, both