Installation Diagram
[ Please keep this instruction]
Please keep this explanation
1.Read and follow the instruction.
2.Warning --- any children without adult accompanying them can not use this
product.
3.All installation of motor power lines should be done by the qualified electr-
Ician.
4.The motor that drives the pump can work under high temperature.Don't to-
uch the motor's crust to prevent from scald.
5.Make sure that the water level should be higher than all the nozzles.
6.This product can only connect to the power that protected by GFCI (the Gr-
ound Fault Current Interrupter), which should be checked and installed by
the qualified electrician, and operated according to the instructions.
7.Do not let anything drop into the gaps between the pump and motor.
8.The water pump can not be refitted, added or deleted.
9.The air switch driver (the push and press style air cell switch) should be in-
stalled above the highest position of the bath when the pump is used.
10.One connection bolt inside the connection box should be earthed to the
earth end of the power circuit board, using the same line with the power
wire,which should not be thinner than 1.5 square millimeters.
11.Warning --- to prevent from getting an electric shock, the earthing type so-
cket protected by the GFCIshould be used.
12.Warning --- to prevent from getting an electric shock, the worn out wires
should be changed in time.
13.Warning --- to prevent from getting an electric shock,, do not use the exte-
nd wire to connect the power. The suitable socket position is required.
The following basic preventive measures should be followed when
installing and using the electric product.
7.Screw the impeller down to the axis. The axis cover pushes the certrifugal
oil ring, which is sealed to the impeller by the RTV glue.
8.Install "O" shape ring (9) to the cover (7) (8).
9.Put the cover (7) (8) in position. Screw down 6 bolts (5).
10.Let the RTV to be hard set for 1 hour before the motor can be started, ot-
herwise the RTV glue will be thrown away. If the water pump is not used in
the CSA bath series, the RTV glue need not to be used.
1.Do not use sealing glue with stone base to the cannulation screw thread.
Please use the RTV silicone sealant, which is specially used in the plastic
fluorin whorl strap. When putting sealant, be carefully not to drop into the
pump to prevent from wrongly sticking to other parts.
2.When the water level in the pump is lower than the nozzles, it is not allow-
ed to start the pump.
3.Please check if the motor circuit diagram, the power voltage and the power
plug are up to the standard.
4.All the metal parts 1.5 m away from the bath should be earthed with the m-
otor.The earth line should be copper wire not thinner than 1.5 square milli-
meters.
5.The earthing lines inside the room should be copper wire not thinner than
4.0 square millimeters.
III. Clue on
We are not responsible for any faults resulted in the using of water pump
and motor without following the operation instructions.Please read the sta-
tement carefully before starting the pump.
Notice: All lines must be fixed according to standard by the pr-
ofessional electrician. The motor must be earthed.
5.Use 1/16 ball bearing and RTV sealing glue. The sealing glue should be
360 degrees in touch with the axis and the centrifugal oil ring. Keep the
sealing glue for 15 minutes.
6.Install the crust (10). Screw down 4 inserting bolts.