4.4 Technical data
max. operating pressure 6 bar (DP34Tri: 5 bar)
Actuator
type
Diaphragm
area
Part-No.
......00001 / 2
Spring
range
Nominal lift
Number of
springs
Filling-
volume
(cm
2
) Standard
with man-
ual emer-
gency
adjustment
(bar) (mm) (Pieces) (Liter)
DP34T
2 x 800
(=1600)
92000 92400
0,2-1,0
30 8
7,6
0,4-1,2
8,8
92202 92402 0,8-2,4 30 16
92206 92406
0,2-1,0
50 8
11
0,4-1,2
13,2
92208 92408
0,8-2,4 50
16
2,1-3,0 30 13,8
92210 92410 1,5-3,0 50 12 13,8
92204 92404
2,4-3,6 30
16
12,2
2,0-4,0 50
13,8
92214 92414
0,2-1,0
65 8
0,4-1,2 16,4
92196 92396 1,0-2,0 65 8
13,6
92198 92398 2,0-4,0 65 16
DP34Tri
3 x 800
(=2400)
92220 92420
0,2-1,0
30 12
11,4
0,4-1,2
13,2
92222 92422 0,8-2,4 30 24
92224 92424
0,2-1,0
50 12
16,5
0,4-1,2
19,8
92226 92426 0,8-2,4 50 24
92228 92428
2,1-3,0 30
18
20,7
1,5-3,0 50 20,7
92230 92430
2,4-3,0 30
24
18,3
2,0-4,0 50
20,7
92232 92432
0,2-1,0
65 12
0,4-1,2 24,6
92238 92438
0,8-2,4 65
24 24,6
0,55-2,4 75
92234 92434 1,0-2,0 65 12
20,4
92236 92436 2,0-4,0 65 24