Technical data

9 Single Tests
62
ARGUS 3u plus/3u NT
After the test time is over, the
ARGUS will display the
cause and the location which
initiated the disconnect.
If the test ran normally, the
ARGUS will display “Active
clearing” on this line.
The test results display:
The bit pattern (e.g. 2^15),
B-channel used (e.g. 02),
Transferred data in KBit (e.g.
10309 KB, K= 1024
*
bits),
The number of bit errors
(e.g.10),
The bit error rate (e.g. 9.7E-
07 = 9.7·10
-7
= 0.00000097),
The evaluation of the results
depends on the error
threshold (OK).
Display of other
characteristic values (in
accordance with ITU-T
G.821)
All values are given in
percentages.
The ARGUS evaluates
whether the test results
satisfy the limits specified in
the CCITT G.821/G.826
under consideration of the
reference connection HRX
(displaying OK or NO).
-Key: Scroll
<MENU>: The ARGUS
returns to the BERT menu.
HRX Defines the hypothetical reference connection
EFS Error Free Seconds
The number of seconds in which no error occurred.
ES821 Errored Seconds
The number of seconds in which one or more errors
occurred.