Technical data

18 Appendix
144
ARGUS 3u plus/3u NT
D) ARGUS Error Messages
Fault
Number
Fault
Class
Cause
.
Description
0
E Network The network is not in a state
defined for DSS1 or 1TR6. It
may be that this state is normal
for a PBX.
1 to 127
B,C,D,E Network DSS1 or 1TR6 causes
150
E ARGUS An error occurred during the
supplementary service test.
Frequent cause: no response
from network
152
B ARGUS The CF-Test was started with
the wrong own number.
.
153
E ARGUS no HOLD is available, but HOLD
is required to test the
supplementary service (ECT,
3pty)
154
E ARGUS CLIR or COLR could not be
tested, since CLIP or COLP is
not available
161
B ARGUS The party called did not answer
within the prescribed time
(approx.10 sec)
162
B ARGUS A call was setup to a remote
subscriber, instead of being
setup as was expected to
your own number.
163
E ARGUS The Auto-Test could not setup a
connection and therefore the
AOC/D supplementary service
could not be tested.
170
ARGUS During the Suppl.services test, a
call came in without a B-channel
(call waiting). Therefore, it was
not possible to accept the call
and test.
199
B ARGUS A call number was entered.
200
ARGUS Internal error
201
A ARGUS Network did not confirm
acceptance of the call (CONN
sent, no CONN_ACK received
from network)