Technical data

15 Configuration
124
ARGUS 3u plus/3u NT
DTMF interval Setting the interval between two DTMF
characters:
The duration of the signal can take a
value between 40ms and 1s (default:
80ms).
Raise or lower the value, using the
,
-
Keys:
In the range 40 - 200ms: in 10ms
increments
In the range 200 - 300ms: in 20ms
increments
In the range 300 - 1000ms: in
100ms increments
When the upper limit is reached
(1000ms), the softkey <
> will
automatically change to a <
> and
vice versa when the lower limit (40ms)
is reached.
Reset to Restores the default settings: Level =
0 dB, Time = 80 ms
Interval = 80 ms
FLASH time Sets the length of a FLASH.
This setting is needed in order to use
special features of a PBX.
The FLASH time can take a value
between 40ms and 1s.
The value can be raised or lowered
using the
,
-Keys:
In the range 40 - 200ms: in 10ms
increments
In the range 200 - 300ms in 20ms
increments
In the range 300 - 1000ms: in
100ms increments
When the upper limit is reached
(1000ms), the softkey <
> will
automatically change to a <
> and
vice versa when the lower limit (40ms)
is reached.