Technical data

13 Level Measuring
110
ARGUS 3u plus/3u NT
Step Load / k Maximum Voltage / V
1 64 ca. 126.0
1)
2 28 ca. 126.0
1)
3 19 ca. 114.0
1)
4 14 ca. 114.0
1)
5 11 ca. 114.0
1)
6 9 ca. 109.4
2)
7 8 ca. 101.8
2)
8 7 ca. 94.6
2)
9 6 ca. 75.0
1)
10 5.5 ca. 75.0
1)
11 5 ca. 75.0
1)
12 4.5 ca. 75.0
1)
13 4.2 ca. 73.9
2)
14 3.9 ca. 71.2
2)
15 2.7 ca. 59.5
2)
1)
The voltage is limited by the power capacity of the
individual components in the ARGUS
2)
The voltage is limited by the maximum power (1300mW)
of the U-interface
When switching the load levels, the power limitations of the
components within the ARGUS and the maximum
permissible power (1300mW) of the U-interface must be
taken into consideration. Therefore, the ARGUS will only
permit the load to be switched another increment when the
specified voltage will not be exceeded.