Technical data
13 Level Measuring
108
ARGUS 3u plus/3u NT
13 Level Measuring
13.1 Level measuring on a BRI access
Level measurement – connected line
The ARGUS measures the level of the received useful
signal. In TE mode, it also measures the phantom feed. The
measurement will be updated continuously.
In the Main menu, use the <
↓
> to select Level
measuring.
Start measurement
The ARGUS will display the
level of the useful signal (e.g.
0.64 V) and the level of the
feed (e.g. 38.2 V).
< R>ON >: add 100Ω
resistor
< R>OFF >: remove 100Ω
resistor
Press <NEW> to setup Layer
1 again - to ensure a
reasonable measurement.
Measurement results:
- Evaluation of the useful signal level:
<< level is too low
>> level is too high
OK Level is in order (0.75V
+20%
-33%
i.e.
from 0.9 V to 0.5 V)
__ no voltage
- Evaluation of the level of the feed
- Type of feed:
NORM Normal feed (40V
+4.25%
-13.75%
i.e.
from 41.7 V to 34.5 V)
REV_ inverted phantom feed
NONE no feed