Operation Manual

18 Configuration
194
ARGUS 145
<DEL> Delete the marked channel from the
list.
Use the channel selection.
IGMP Version Entry of the IGMP protocol version
Max.
Switchover time
Enter the switchover (zapping) time:
This is the period of time during the test within which the ARGUS
must have received the data of the (next) TV channel. If the ARGUS
does not receive the data of the TV channel within this period of
time, it will consider the test to have failed and will accordingly
display “FAIL”.
Minimum: 1 sec. 25 sec.
Profile name Entry of a name for the Scan profile
MDI analysis:
Mode Select either Automatic or Manual:
Manual: The address of the TV channel, whose data stream should
be analysed, must be entered under Multicast IP and Port. The time
span within which the ARGUS will attempt to receive a data stream
is unlimited.
Automatic: The ARGUS will search for the data stream with the
highest data rate of one of the TV channels available. You must
enter the time span within which the ARGUS will attempt to receive a
data stream under Scan time.
Scan time The time span within which the ARGUS will attempt to receive a data
stream.
Multicast IP The multicast IP of the TV channel whose data stream should be
analyzed.
Port The port number of the TV channel whose data stream should be
analyzed.