Datasheet

7 Operation on a VDSL Access
62 ARGUS 141
Settings: Explanation:
Access parameters
Phys. parameters:
VDSL Access parameters for the VDSL connection
Rated value
Use the keypad to enter the upstream and downstream comparison
values for the bitrate [kbit/s]. If the current bitrates on the VDSL
connection exceed the rated values, the ARGUS will display "OK“,
otherwise it will display "FAIL“.
Default setting: d: 0 and u: 0
FW
Selection of the firmware (FW) in the VDSL chipset.
The following options are available - FS10.3 and FS10.4.
Default setting: FS10.3 (recommended)
Carrier set
Selection of the VDSL carrier set.
The following sets are available: A43, B43, V43.
Default setting: A43, B43, V43
Protocol: Selection of the transfer protocol that the ARGUS should use for the
test (e.g. for an IP test).
Protocols for ADSL:
PPPoE (PPPoEoA) - Point-to-Point Protocoll over Ethernet
PPPoA - Point-to-Point-Protokoll over ATM
EoA (IPoE, IPoEoA) - Ethernet over ATM
IPoA - Internet Protokoll over ATM
Default setting: PPPoE
MAC / VLAN: MAC (Media Access Control) and
VLAN (Virtual Local Area Network)
MAC address Display and selection of the MAC addresses.
The first two MAC addresses cannot be changed.
If the default MAC address is selected, the ARGUS will use its own
MAC address.
Default setting: Default MAC address
If Dynamic MAC Address is select a different MAC address will be
used for each synchronization.
A third MAC address can be entered: Mark and then press
<Edit>.