NOTICE: This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept any interface received, including interface that may cause undesirable operation. This equipment has been tested and complied with the limits for a Class a digital device, pursuant to Part 15 of the FCC Rules.
Using the ArgoxScan 8110/8120/8150/8250/8310/8312 The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code. Successful scanning shall be obtained by tilting the scanner with respect to the barcode to avoid direct reflections that impair the reading performance, especially for 2D barcode.
CONTENTS Chapter 1 Introduction Introduction…………………………..………………. Default Setting ………………………………………. ArgoxScan8110/8120 specification ……………….. ArgoxScan8150/8250/8310/8312 specification ….. Programming the ArgoxScan…………………….. 1 2 4 7 10 Chapter 2 Parameter Setting Interface……………………………………………….… Interface Selection ………………………………….. Keyboard wedge ……………………………………. RS-232 …………………………………………….…. Wand Emulation …………………………….………. Pin Assignments ……………………………………. 12 12 13 18 21 24 System Control……………………………………….
Telepen ………………………………………………. 80 Standard 2 of 5 ……………………………………… 82 China Post …………………………………………… 84 Italian pharmacode ………………………………… 86 Code 16K …………………………………..………… 88 PDF-417 ……………………………………………… 90 EAN UCC Composite……………………………….. 92 RSS-14 ………………………………………………. 94 RSS-Limited…………………………………..…… 96 RSS-Expanded…………………………………..….. 98 Micro-PDF…………………………………..………..
0
Introduction Installation- Keyboard Wedge 1) 2) 3) 4) First of all, you must switch off power for the terminal/computer. Disconnect the keyboard cable from the back of the terminal/computer. Connect the appropriate interface cable to the scanner and to the terminal/computer. Turn the terminal/computer power on. RS-232 1) 2) 3) 4) 5) Disconnect power to the terminal/computer. Connect the appropriate interface cable and external power supply (DC adapter) to the scanner.
Default setting For each barcode shown as below: Code Type Read Enable 8110 / 8120 UPC-A UPC-E EAN-13 EAN-8 Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 Code-93 Code-11 MSI/Plessey UK/Plessey Telepen Standard 2 of 5 RSS-14 RSS-Limited RSS-Expanded China Post Italian Pharmacode.
Read Enable Code Type 8250 8150 8310 Checksum Checksum Code Verification Transmission ID Enable Enable 8312 UPC-A UPC-E EAN-13 EAN-8 Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 Code-93 Code-11 MSI/Plessey UK/Plessey Telepen Standard 2 of 5 China Post Italian Pharmacode.
ArgoScan 8110 / 8120 Specification Model 8110 Model 8120 Operational Light Source 660 nm Visible Red LED Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field 0-80 mm 0-150 mm (CODE 39, (code 39, PCS=90%, 20mils) PCS=90%, 20mils) Scanning Width Scan Speed Resolution 80 mm at contact 75mm at contact 50 scans/sec 100 scans/sec 4mils, Code39, PCS=90%, on contact 5mils, Code39, PCS=45%, on contact Print Contrast Scanning Angle Decode Capability 30% or more Pitch: 60° Skew:
Cable – K/B wedge Straight 2.0 m Cable – universal Straight 2.3 m type Connector type RJ-45 phone jack connector Case material ABS Cushion material Rubber Electrical Input Voltage Power - Operating Power - Standby 5 VDC ± 0.
Programming Programming method Program upgrade Manual (Reading special barcode) DOS command through RS-232, Windows configuration program (8110) Enabled built-in flash memory (8110) Programmable Code type selection, check digit characteristics selection Decoding option Decoding option Transmitted character delay, Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard emulation type (intermessage delay, keyboard type and keyboard language)
ArgoScan 8150 / 8250 / 8310 / 8312 Specification Model Model 8150/8250 8310/8312 Operational Light Source 660 nm Visible Red 630 nm Visible Red LED Optical System LED 2048 pixel CCD (Charge-coupled device) Depth of Scan Field 0-250 mm Up to 600mm (CODE 39, (CODE 39, PCS=90%, 20mils) PSC=90%, 20mils) Scanning Width 120 mm 160mm Scan Speed 200 scans/sec 450 scans/sec Resolution 0.1mm(4mils); 0.
Width-handle 26 mm 30 mm Width-head 74 mm 78 mm Depth-handle 51 mm 56 mm Depth-head Weight Cable – K/B wedge Cable – universal type Cable- USB Connector type Case material Cushion material 35 mm 35 mm 150 g (cable not 176 g (cable not included) included) Straight 2.0 m Coiled 2.5 m Straight 2.3 m Coiled 2.5 m Straight 2.0 m Coiled 2.
Operating Temperature Storage 0 (32 to 45 -40 (-40 Humidity 0 to 113 ) to 60 to 140 ) (32 -20 (-4 to 45 to 113 ) to 60 to 140 ) 5% to 90% relative humidity, non-condensing Light Level Up to 60000 (8150); Up to 70000 Lux. 80000 (8250) Lux. Shock Contaminants 1.
Programming the ArgoScan 8110/8120/8150/8250/8310/8312 To program the 8110/8120/8150/8250/8310/8312, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented. To program each option, you must: 1. Scan the Program barcode on the parameter setting part. 2. Enter the option mode by scanning the Option Bar Code (also on the Parameter setting part). 3.
Program Barcode Program Option Bar Code Option Alphanumeric Entry Keyboard Wedge 00 Interface RS-232 01 selection Wand emulation 02 USB 03 Keyboard/RS-232 04 Auto detection Reserved 05 Exit Option Barcode Back Fold Out Exit Barcode Finish barcode 11
Interface Selection This decoder built-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulation, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface. By plugging different cables, setting right interface, then the scanner will be changed to another interface.
Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer. Scanner must be selected to the appropriate host interface cable converter.
Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard” to select country at “language” item. For details, please refer to your DOS or WINDOWS user’s manual. Keyboard Speed: By selecting, you can change output speed of scanner to match with host computer.
Keyboard layout Keyboard speed USA 00 Belgium 01 Danish 02 France 03 Germany 04 Italian 05 Portuguese 06 Spanish 07 Swedish 08 Switzerland 09 UK 10 Latin American 11 Japanese 12 0-8 00-08 0 : high clock rate 01 * (8150/8250) 8 : low clock rate 03 Disable 00 Enable 01 Alphabetic key 00 Numeric keypad 01 *(83XX/8120) Function key Numeric key (Num lock state only) Alt+Keypad 15 02 Exit
Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on. Inter-character delay: This delay is inserted after each data characters transmitted.
Program Option Bar Code Option Alphanumeric Entry Caps lock”ON” 00 Caps lock”OFF” 01 Disable 00 Enable 01 00-99 msec 00-99 Caps lock Power-on simulation 02 Inter-character delay 00-99 10 msec 00-99 10 Block transmission delay Exit 17
RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII Code13 16) Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol. RTS/CTS-If the scanner wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication.
Program Option Bar Code Option Alphanumeric Entry Flow control None 00 RTS/CTS 01 Xon/Xoff 02 ACK/NAK 03 00-99 (msec) 00-99 00 Inter-character delay 00-99 (10 msec) 00-99 00 Block transmission delay 00-99 (100 msec) 00-99 20 Response delay Exit 19
Program Option Bar Code Option Alphanumeric Entry Baud rate Parity 300 BPS 00 600 BPS 01 1200 BPS 02 2400 BPS 03 4800 BPS 04 9600 BPS 05 19200 BPS 06 38400 BPS 07 None 00 Odd 01 Even 02 8 bits 00 7 bits 01 One bit 00 Two bits 01 Data bit Stop bit Exit 20
Wand Emulation (for 8110/8150/8250) Bar/space polarity: High/low- Black will be transmitted as a high voltage level (+5) and space as low level (0V). Low/high- Black will be transmitted as a low voltage level (0V) and space as high level (+5). Initial polarity: You must make sure what is Initial polarity of your wand decode device in stand-by (idle). So, initial signal state as a High voltage level (+5) or Low voltage level (0V).
Wand Emulation (for 8110/8150/8250) Output speed: This setting is same as serial transmission baud rate, and it must be approbated your wand decode resolution. The unit of speed is a width of minimum narrow bar. Margin delay: It is a timer of zone like space zone of barcode label margin. The width of margin time will be added before and after in each barcode data automatically when it is transmitted. Transmit delay: It is a delay time between barcode data output.
Program Option Bar Code Option Alphanumeric Entry Output speed 620 pps 00 1250 pps 01 2500 pps 02 5000 pps 03 10000 pps 04 20000 pps 05 *pps: pixel per second 00 00 Reserved Reserved 00-99 (10 pixel) 00-99 15 Margin delay 00-99 (10 msec) 00-99 30 Transmit delay 23 Exit
Pin Assignments AS Series 8-pin RJ-45 Connector Pin RS-232 Keyboard 1 VCC (+5V) VCC (+5V) 2 TXD NC 3 NC CLK / PC 4 NA DATA / PC 5 CTS DATA / KB 6 RXD NC 7 RTS CLK / KB 8 GND GND 1 2 3 54 6 7 8 9 10 1 2 3 5 46 7 8 8-pin 10-pin AS Series 10-pin RJ-45 Connector Pin RS-232 Keyboard 1 I/F I/F 2 VCC (+5V) VCC (+5V) 3 TXD NC 4 NC CLK / PC 5 GND DATA / PC 6 CTS DATA / KB 7 RXD NC 8 RTS CLK / KB 9 GND GND 10 NC GND 24
Keyboard Wedge Combo Connector (To Host Side): 4 Pin Mini-DIN 6P Male DIN 5P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4 VCC (+5V) VCC (+5V) 5 CLK / PC CLK / KB 6 NC NC 5 DIN 5P Female Connector 3 2 1 Mini-DIN 6P Male Connector 6 4 5 3 2 1 RS-232 DB-9F Connector (To Host Side): Pin Definition 1 NC 2 TXD 3 RXD 4 NC 5 GND 6 NC 7 CTS 8 RTS 9 VCC (+5V) 25 5 4 3 2 1 9 8 7 6
Keyboard Wedge PS/2 Connector (To Host Side): Pin Mini-DIN 6P Male Mini-DIN 6P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4 VCC (+5V) VCC (+5V) 5 CLK / PC CLK / KB 6 NC NC 4 6 3 5 2 1 Mini-DIN 6P Female Connector Mini-DIN 6P Male Connector 26 6 4 5 3 2 1
27
Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate-The trigger button acts as a toggle switch. Press button to activate or stop scanning.
Program Option Bar Code Option Alphanumeric Entry Scanning mode Good-read off 00 Momentary 01 Alternate 02 Timeout off 03 Continue 04 Test only 05 01-99 (second) 00-99 06 Stand-by duration 01-99 (10 msec) 01-99 50 Double read timeout Double confirm 00-99 00-09 (00: no double 00 confirm) 00-64 00-64 (verifications) 30 Supplement Check Counter 29 Exit
Scan Global min./max. code length: These are to define the min/ max readable code length of all symbologies. Code length less than min. code length or more than max. code length will not be read. In popular, you can set the same value for both min. and max. reading length to force the fixed length barcode decoded. The values of setting have no effect on certain symbologies with fixed length. You can specify the settings for individual barcode by the min/max code length setting of each barcode.
Program Option Bar Code Option Alphanumeric Entry 00-99 00-99 (00-64) (AS-8120) Global min. code length 04 00-99 04-99 (00-64) 99 Global max.
Scan Position indication (8110 excluded): If the function is enabled, scan beam will flash as a pointer to help you aim at the bar code prior to scanning. The code will not be scanned until you press the trigger. Stand mode selection: Normally activated with continuous mode. If it is set as LED “off”, the scanner red beam will turn off automatically in case not used, but will turn on again immediately when scanning bar codes.
Program Option Bar Code Option Alphanumeric Entry Position indication *7AL* Disable 00 30 second 01 60 second 02 90 second 03 120 second 04 150 second 05 180 second 06 Continue 07 LED ‘’on’’ 00 LED ‘’off’’ 01 Disable 00 Enable 01 Stand mode selection *7AM* PCS Enhancement (For 8120) Exit 33
Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the scanner will beep buzzer to indicate a good barcode reading, and its Beep loudness, Beep tone freq. and Beep tone duration are adjustable. Beep loudness/Beep tone freq.
Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01 Disable 00 Enable 01 Disable 00 Enable 01 00-07 00-07 Power on alert LED indication Beeper indication 07 Beep loudness 00-99 (100Hz) 00-99 26 Beep tone freq.
UPCA Format Leading Zero Data Digits (11 Digits) Check Digit Read: Enable or disable the read function. Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. It will beep instead of reading anything when the truncate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of the Ending.
Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01 Disable 00 Enable 01 0-15 00-15 Read Check-sum transmission 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code Code ID setting Exit 37
UPCA Insertion group number selection: The scanner offers max. two insertion groups for one symbology. By setting one or two digits to indicate which insertion group you want to insert. You may refer to Character insertion. The function is to insert specific characters as a group into transmitted data of selected symbologies. Enable the group insertion by selecting the group number. Example: Group 2 set 02 or 20. Group 1 and 4 set 14 or 41.
Program Option Bar Code Option Alphanumeric Entry 00-44 00-44 00 Insert group number selection Supplement digits (For 8110/8150/8250) Supplement digits (For 8120/8310/8312) None 00 2 digits 01 5 digits 02 UCC/EAN 128 03 Auto detection 04 None 00 2 digits 01 5 digits 02 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 128 05 5, UCC/EAN 128 06 All 07 Exit 39
UPCA Truncation / Expansion: The leading “0” digits of UPCA data characters can be truncated when the function is enabled.
Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01 None 00 Truncate leading 01 Truncation/ Expansion (For 8110) Truncation/ zero Expansion (For Expand to EAN13 02 8120/8150/8250/ 8310/8312) The Exit 41
UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code Code ID setting Exit 43
UPCE Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Supplement digits: Format Leading Zero Data Digits Check (6 Digits) Digit Supplement Digits 2 or 5 or UCC/EAN 128 Expansion: The expansion function is used only for UPCE and EAN-8 code reading. It extends to 13-digits with “0” digits when the feature is enabled. Example: Barcode “0123654” Output: “0012360000057” UPCE-1: Enable scanner to read UPCE with leading digit 1.
None 00 2 digits 01 Supplement digits 5 digits 02 (For 8120/8310/8312) 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 128 05 5, UCC/EAN 128 06 All 07 Disable 00 Enable 01 None 00 Truncate leading 01 Truncation/Expansion (For 8110) Truncation/Expansion zero (For 8120/8150/8250/ Expand to EAN13 02 8310/8312) Expand to UPCA 03 Disable 00 Enable 01 Disable 00 Enable 01 Expansion *OAM* UPCE-1 Exit 45
EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Truncate leading zero: Refer to Truncation / Expansion of UPCA.
0-15 00-15 00 Truncate ending Disable 00 Enable 01 Truncation leading zero Exit 47
EAN-13 Code ID setting: Refer to page 36 Insertion group number selection of UPCA. Insertion group number selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Data Digits (12 Digits) Check Digits Supplement Digits 2 or 5 or UCC / EAN 128 ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two kinds of barcode for book and magazines.
None 00 2 digits 01 Supplement digits 5 digits 02 (For 8110/8150/8250) UCC/EAN 128 03 Auto detection 04 None 00 2 digits 01 Supplement digits 5 digits 02 (For 8120/8310/8312) 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 05 128 06 5, UCC/EAN 07 128 All Disable 00 Enable 01 ISBN/ISSN conversion Exit 49
EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
0-15 00-15 00 Truncate ending Code ID setting Two characters 00-ffH, 00-ffH 00-ffH ASCII < FF > code 00-44 00-44 00 Insert group number selection Exit 51
EAN-8 Supplement digits: Format Data Digits (7 Digits) Check Digits Supplement Digits 2 or 5 or UCC/EAN 128 Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE.
Disable 00 Enable 01 None 00 Truncate leading 01 Truncation / Expansion (For 8110) Truncation / zero Expansion Expand to EAN13 02 Disable 00 Enable 01 (For 8120/8150/8250 /8310/8312) Expansion Exit 53
Code 39 Read: Format Start “ ” " Data Digits ( Variable) Checksum (Optional) End “ ” " Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect.
Disable 00 Enable 01 Disable 00 Enable 01 00-64 00-64 Check-sum verification Check-sum transmission 00 Max. code length 00-64 00-64 00 Min.
Code 39 Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z). Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embedded appending code (space for Code-39).
Standard 00 Full ASCII 01 Disable 00 Enable 01 Disable 00 Enable 01 Format Append Start/end transmission Exit 57
Interleaved 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01 00-64 00-64 Check-sum transmission 00 Max. code leading 00-64 00-64 00 Min.
Industrial 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01 00-64 00-64 Read 00 Max. code length 00-64 00-64 00 Min.
0-15 00-15 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code 00-44 00-44 Code ID setting 00 Insert group number selection Exit 61
Matrix 2 of 5 Eur Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01 00-64 00-64 Checksum Transmission 00 Max. code length 00-64 00-64 00 Min.
Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01 00-64 00-64 Checksum Transmission 00 Max. code length 00-64 00-64 00 Min.
Codabar Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39.
Code-128 Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character. The first FNC1 will be translated to “]C1”,and next to be a field separator code as (1D16).
0-15 00-15 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code <#> 00-44 00-44 Code ID setting 00 Standard 00 UCC/EAN-128 01 Insert group number selection Format Exit 69
Code-128 Append: When the function is enabled, it won' t show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn' t have FNC2 code. UCC/ EAN 128 ID setting: To setting the code ID for UCC/EAN-128 output format. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you can reassign second or after a FNC1 for your usage. The default of ASCII code is (1D16).
Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00-64 00-64 00 Max. code length 00-64 00-64 00 Min.
00-ffH ASCII 00-ffH code <&> 00-44 00-44 Code ID setting 00 Insert group number selection Exit 73
Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01 00-64 00-64 Checksum Transmission 00 Max. code length 00-64 00-64 00 Min.
MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max.
Mod 11/10 03 Disable 00 Enable 01 00-64 00-64 Checksum Transmission 00 Max. code length 00-64 00-64 00 Min.
UK/plessey Read: Format Data Digits (Variable) Checksum1+2 (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01 00-64 00-64 Checksum Transmission 00 Max. code length 00-64 00-64 00 Min.
Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
00-64 00-64 00 Max. code length 00-64 00-64 00 Min. code length 0-15 00-15 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code 00-44 00-44 Code ID setting 00 Insert group number selection $% & ' () *,+-' .
Standard 2 of 5 Read: Format Data Digits (Variable) Checksum1 (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
*JAC* Disable 00 Enable 01 00-64 00-64 Check-sum transmission 00 Max. code length 00-64 00-64 00 Min.
China Post Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01 00-64 00-64 Read 11 Max. code length 00-64 00-64 11 Min.
0-15 00-15 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code 00-44 00-44 Code ID setting 00 Insert group number selection Exit 85
Italian Pharmacode (Code 32) Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Leading “A”: If this function is enabled, each prefix of data shall be A.
00-64 00-64 09 Min.
Code-16K (for 8250/8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
00-44 00-44 00 Insert group number selection Exit 89
PDF-417 (for 8250/8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01 0-15 00-15 Read 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code < 00-44 00-44 > Code ID setting 00 Disable 00 Enable 01 Insert group number selection *QAJ* Escape sequence transmit 91 Exit
EAN UCC Composite (for 8312) For the coupon extended code application. Coupon extended code is a supplementary barcode that is printed to the right of the UPC/EAN in UCC/EAN-128 symbology. Program Option Bar Code Option Alphanumeric Entry *YAA* Disable 00 Enable 01 00-64 00-64 Read 64 *YAD* Max. code length 00-64 00-64 01 *YAE* Min.
*YAH* 00-ffH 00-ffH ASCII code < RC > 00-44 00-44 Code ID setting *YAI* 00 Insert group number selection *YAK* Disable 00 Enable 01 UCC / EAN128 emulation Exit 93
RSS-14 Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to Transmission, Code ID transmission must be set as AIM ID enable. Then ]C1 will be identified as prefix of barcode data transmission.
0-15 00-15 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code < R4 > 00-44 00-44 Code ID setting 00 Disable 00 Enable 01 Insert group number selection UCC/EAN128 emulation Exit 95
RSS-Limited Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
00-ffH ASCII 00-ffH code < RL > 00-44 00-44 Code ID setting 00 Disable 00 Enable 01 Insert group number selection UCC/EAN128 emulation Exit 97
RSS-Expanded Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
00-99 00-99 01 Min.
Micro-PDF (for 8312) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
00-44 *XAI* 00-44 00 Insert group number selection None 00 *XAJ* GLI protocol 01 Escape sequence ECI protocol 02 transmit Exit 101
String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies. Up to 22 ASCII characters can be defined as Prefix or Suffix. Format of barcode data transmission: Prefix Name Preamble ID Code Barcode Length Data ID Postamble Insert groups .
Program Option Bar Code Option Alphanumeric Entry None 00 1-22 characters 00-ffH ASCII Prefix characters code setting None 0D 1-22 characters 00-ffH ASCII Suffix characters code setting Exit 103
String setting / Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data automatically for all symbologies. However, the transmission will not activate unless Preamble / Postamble transmission is enabled. Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, Postamble will be appended after the data is transmitted.
Program Option Bar Code Option Alphanumeric Entry None 00 1-22 characters 00-ffH ASCII Preamble characters code setting Disable 00 Enable 01 None 00 1-22 characters 00-ffH ASCII Preamble transmission Postamble code characters setting Disable 00 Enable 01 Postamble transmission Exit 105
String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The scanner supports inserting two groups with each group 22 characters into transmitted data of selected symbologies. The two groups can be inserted into scanned data of the selected symbologies or positioned at leading / ending of data. There are total four groups for utilization. Insert data group position: To define the position of a group to insert into bar code data.
5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. 6) Insert data group 1-4 position. Please refer to ChapterTransmission, page 65 and in specific barcode that you want to use. 7) Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is “00” to indicate no character insertion. Beside, make sure insertion positions are not greater than the symbols; otherwise the insertion data is not effective.
String setting / Transmission (Insert Group Characters) Program None 00 1-22 characters 00-ffH ASCII Insert G3 characters code setting None 00 1-22 characters 00-ffH ASCII Insert G4 characters code setting 00-63 00-63 (00: no insertion) 00 00-63 00-63 (00: no insertion) 00 00-63 00-63 (00: no insertion) 00 Insert data group 1 position Insert data group 2 position Insert data group 3 position 108
00-63 00-63 (00: no insertion) 00 Insert data group 4 position Exit 109
String setting / Transmission (Others) Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before Code Data or After Code Data when it is transmitted. Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected.
Before code data 00 After code data 01 Disable 00 Proprietary ID 01 AIM ID 02 Disable 00 Enable 01 Disable 00 Enable 01 Disable 00 Upper case 01 Lower case 02 Code ID position Code ID transmission Code length transmission Code name transmission Case conversion *For barcode data only Exit 111
A B0C8DFEHGJIJKMLHCFNPOJQ KJLRNRC8D S2KJIUT L2YJNPZ[GFQ \^] _0C8D`KMK a[CFZ,Q KJIbV a,V W V CFQ Q Y8c d CODABAR-PARA (8110 *) CODE-11 PARA CODE-128 PARA * CODE-39 PARA * CODE-93 PARA EAN-13 PARA * 112 V W X
PDF-417 (8250/8312 *) STANDRAD-25 PARA CODE-16K e-f-g)h2i EAN-8 PARA * INDUSTRIAL-25 PARA UPCE PARA * 113
INTERLEAVED-25 PARA * MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA * UK/PLESSEY PARA RSS Micro-PDF (8312 *) 114
j4k l m n ASCII Code Table } }~ £ ¥ § © ¡ ¦ £ ¥ § © ¡ ¦ ) ) =^% }`^ ) ` ) ) £ ¥ § © ¨t® = ± ´ ¡) ´ ¦p¨ ª « ~ ~= @ ^° ` ± ³ ¨ ± = ^ · ¹ º » ¼ ½ ¿ Á Ã Å ´ Ï Ó × Û µ ¡ ¦ £ ² ¥ § © Ë ¢ Ô Ü ~ Æ Ð Ø ¬ ³ Ç } 115 opk^qpr`mts^u k^v q w:x m wtypmHk`z { s | 44} 4} @~ ) p )) p
Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your AS-8110/8120/8150/8250/8310/8312, scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code.
Query present scanner firmware version Program Firmware version list If you wish to display the firmware version, scan the “Firmware version list” barcode. Exit Reset scanner to factory default settings Program WARNING: Default value initialization If you wish to return the AS-8110/8120/8150/8250/8310 to all the factory default settings, scan the Default value initialization bar code.
0 A 1 B 2 C 3 D 4 E 5 F 6 7 8 Finish 9 118