NOTICE: This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept any interface received, including interface that may cause undesirable operation. This equipment has been tested and complied with the limits for a Class a digital device, pursuant to Part 15 of the FCC Rules.
Using the ArgoxScan 8000/8120/8150/8250/8310/8312 The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code. Successful scanning shall be obtained by tilting the scanner with respect to the barcode to avoid direct reflections that impair the reading performance, especially for 2D barcode.
Introduction Installation- Keyboard Wedge 1) 2) 3) 4) First of all, you must switch off power for the terminal/computer. Disconnect the keyboard cable from the back of the terminal/computer. Connect the appropriate interface cable to the scanner and to the terminal/computer. Turn the terminal/computer power on. RS-232 1) 2) 3) 4) 5) Disconnect power to the terminal/computer. Connect the appropriate interface cable and external power supply (DC adapter) to the scanner.
Programming the ArgoScan 8110/8120/8150/8250/8310/8312 To program the 8110/8120/8150/8250/8310/8312, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented. To program each option, you must: 1. Scan the Program barcode on the parameter setting part. 2. Enter the option mode by scanning the Option Bar Code (also on the Parameter setting part). 3.
Interface Selection Keyboard Wedge RS-233 Wand Emulation (8110/8150/8250) USB Keyboard /RS232/USB * Auto detection Note: -Default Keyboard Layout USA * Belgium Danish 2
Keyboard Layout - Continued France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American Japanese 3
RS-232 Flow Control None * RTS/CTS Xon/Xoff ACK/NAK RS-232 Baud Rate Setting 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS * 4
RS-232 Baud Rate Setting (Continued) 19200 BPS 38400 BPS RS-232 Parity Setting None * Odd Even RS-232 Data Bit Setting 8 bits * 7 bits 5
Pin Assignments AS Series 8-pin RJ-45 Connector Pin RS-232 Keyboard 1 VCC (+5V) VCC (+5V) 2 TXD NC 3 NC CLK / PC 4 NA DATA / PC 5 CTS DATA / KB 6 RXD NC 7 RTS CLK / KB 8 GND GND 1 2 3 4 5 6 7 8 9 10 1 2 3 5 46 7 8 8-pin 10-pin AS Series 10-pin RJ-45 Connector Pin RS-232 Keyboard 1 I/F I/F 2 VCC (+5V) VCC (+5V) 3 TXD NC 4 NC CLK / PC 5 GND DATA / PC 6 CTS DATA / KB 7 RXD NC 8 RTS CLK / KB 9 GND GND 10 NC GND 6
Keyboard Wedge Combo Connector (To Host Side): 4 Pin Mini-DIN 6P Male DIN 5P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4 VCC (+5V) VCC (+5V) 5 CLK / PC CLK / KB 6 NC NC 5 DIN 5P Female Connector 3 2 1 Mini-DIN 6P Male Connector 6 4 5 3 2 1 RS-232 DB-9F Connector (To Host Side): Pin Definition 1 NC 2 TXD 3 RXD 4 NC 5 GND 6 NC 7 CTS 8 RTS 9 VCC (+5V) 7 5 4 3 2 1 9 8 7 6
Keyboard Wedge PS/2 Connector (To Host Side): Pin Mini-DIN 6P Male Mini-DIN 6P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4 VCC (+5V) VCC (+5V) 5 CLK / PC CLK / KB 6 NC NC 4 6 3 5 2 1 Mini-DIN 6P Female Connector 6 Mini-DIN 6P Male Connector 8 5 4 3 2 1
Scan Mode Good-read off Momentary * Alternate Timeout off Continue Test only Stand Mode Enable Stand mode + 9
Suffix Characters Setting (Keyboard Wedge & USB) Enter * Tab None 10
Enable Barcode Industrial 2 of 5 Matrix 2 of 5 Eur Standard 2 of 5 Codabar Code 93 Code 11 MSI/Plessey UK/Plessey Telepen China Post Italian Pharmacode (Code 32) Code-16K (for 8250/8312) 11
Enable Barcode - Continued EAN UCC Composite (for 8312) RSS-14 RSS-Limited RSS-Expanded Micro-PDF (for 8312) Note: All other barcodes not listed in the table are set to be enabled in default.
UPCA Supplement digits (for 8120/8150/8250) None * 2 digits 5 digits UCC/EAN 128 Auto detection 13
UPCA Supplement digits (for 8310/8312) None * 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 14
UPCE Supplement digits (for 8120/8150/8250) None * 2 digits 5 digits UCC/EAN 128 Auto detection 15
UPCE Supplement digits (for 8310/8312) None * 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 16
UPCA Truncation/Expansion None * Truncate leading zero Expand to EAN-13 UPCE Truncation/Expansion None * Truncate leading zero Expand to EAN-13 Expand to UPCA UPCE Expansion None * Truncate leading zero 17
EAN-13 Supplement digits (for 8120/8150/8250) None * 2 digits 5 digits UCC/EAN 128 Auto detection 18
EAN-13 Supplement digits (for 8310/8312) None * 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 19
EAN-8 Supplement digits (for 8120/8150/8250) None * 2 digits 5 digits UCC/EAN 128 Auto detection 20
EAN-8 Supplement digits (for 8310/8312) None * 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 21
ISBN/ISSN Conversion Disable * Enable EAN-8 Expansion None * Truncate leading zero 22
Code 39 Check-sum setting Verification Disable * Verification Enable Transmit Disable * Transmit Enable Code 39 Format setting Standard * Full ASCII Append Disable * Append Enable Start/End Tx Disable * Start/End Tx Enable 23
CODABAR-PARA (8110 *) CODE-11 PARA CODE-128 PARA * CODE-39 PARA * CODE-93 PARA EAN-13 PARA * 24
PDF-417 (8250/8312 *) STANDRAD-25 PARA CODE-16K EAN-8 PARA * INDUSTRIAL-25 PARA UPCE PARA * 25
INTERLEAVED-25 PARA * MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA * UK/PLESSEY PARA GS1 Databar Micro-PDF (8312 *) 26
ASCII Code Table ! " # '% & ( ( )-, *16 748 ! < = > @'A B CD> H B )', H B *'8 # $ 5 ; ? G M Q S 9 V W U J "16 Z[< +E8 ^ +E8D>_ *1< ( < >g< Q 3 * + . ! " # $ 5 ; ? G M P R U J Q 3 $ . $ .5 . ; .? .G .M . P .R .U .E$Y# + SD\ .E$ $ .E$ 5 31>d`e( f JF( >df P R # $ % ) ! *'! + /102" *134$ / 9 : *13 5 + 9 : *13 ; +E0F9 *131? +1%-I % JLK JN3NK / OL% + 9 Q Q +1! 3TJF% Q / "T9 +TX ! . /') Q +E/13 ] 9 . . .
Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your AS-8110/8120/8150/8250/8310/8312, scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code.
Query present scanner firmware version Program Firmware version list If you wish to display the firmware version, scan the “Firmware version list” barcode. Exit Reset scanner to factory default settings Program WARNING: Default value initialization If you wish to return the AS-8110/8120/8150/8250/8310 to all the factory default settings, scan the Default value initialization bar code.
0 A 1 B 2 C 3 D 4 E 5 F 6 7 8 Finish 9 30