NOTICE: This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept any interface received, including interface that may cause undesirable operation. This equipment has been tested and complied with the limits for a Class a digital device, pursuant to Part 15 of the FCC Rules.
Using the ArgoxScan 8000 The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code. Successful scanning shall be obtained by tilting the scanner with respect to the barcode to avoid direct reflections that impair the reading performance.
CONTENTS Chapter 1 Introduction Introduction…………………………..………………. Default Setting.………………………………………. ArgoxScan8000 specification.…………………….. Programming the ArgoxScan 8000 Series Scanner 1 2 3 6 Chapter 2 Parameter Setting Interface……………………………………………….… Interface Selection.………………………………….. Keyboard wedge.……………………………………. RS-232.…………………………………………….…. Pin Assignments.……………………………………. 8 8 9 14 17 System Control………………………………………. Indication. …………………………………………… Transmission………………………………………… Scan.………………………………………………….
Telepen.………………………………………………. Standard 2 of 5 ……………………………………… RSS-14.………………………………………………. RSS-Limited…………………………………..…… RSS-Expanded…………………………………..….. China Post …………………………………………… Italian pharmacode ………………………………… 74 76 78 80 82 84 86 Appendix………………………………………………… Test Chart.……………………………………………. ASCII Code Table …………………………………… Parameter setting List.……………………………….
0
Introduction Installation- Keyboard Wedge 1) 2) 3) 4) First of all, you must switch off power for the terminal/computer. Disconnect the keyboard cable from the back of the terminal/computer and connect to the interface cable of the scanner. Connect the interface cable of the scanner to the terminal/computer. Turn the terminal/computer power on. RS-232 1) 2) 3) 4) 5) Disconnect power to the terminal/computer. Connect the external power supply (DC adapter) to the interface cable of the scanner.
Default setting For each barcode shown as below: V = Enabled as default setting - = Not supported Empty space = Not enabled at default setting Code Type UPC-A UPC-E EAN-13 EAN-8 Code-39 Interleaved 2 of 5 Industrial 2 of 5 IATA Matrix 2 of 5 Codabar Code-128 Code-93 Code-11 MSI/Plessey UK/Plessey Telepen Standard 2 of 5 GS1 DataBar Omnidirectionl GS1 DataBar Limited GS1 DataBar Expanded China Post Italian Pharmacode.
AS-8000 Specification ArgoScan 8000 series Specification Model AS-8000 series Operational Light Source 660 nm Visible Red LED Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field 0-180 mm (CODE 39, 500Lux, PCS=90%, 20mils) Scanning Width 50 mm wide @ 10mm Scan Speed Resolution 100 scans/sec 0.
Connector type Crimp type female connector Case material ABS plastic Cushion material TPR Electrical Input Voltage 5 VDC ± 0.25V Power - Operating Max. 750 mW Power - Standby Current - Operating 150 mW Max.
Programming Programming method Manual (Reading special barcode), DOS command through RS-232 (RS-232 model) Programmable Code type selection, check digit characteristics selection, Decoding option Transmitted character delay, Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard emulation type (intermessage delay, keyboard type and keyboard language) Serial interface type (ACK/NAK, Xon/Xoff, RTS/CTS, good read LED control, start/stop bits
Programming the ArgoScan 8000 Series Scanner To program the 8000 series scanner, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented. To program each option, you must: 1. Scan the Program barcode on the parameter setting part. 2. Enter the option mode by scanning the Option Bar Code (also on the Parameter setting part). 3.
Program Barcode Program Option Bar Code Scanning mode Option Alphanumeric Entry Good-read off 00 Momentary 01 Alternate 02 Timeout off 03 Continue 04 Test only 05 Exit Option Barcode Back Fold Out Exit Barcode Finish barcode 7
Interface Selection This decoder built-in scanner comes in three models and supports interfaces such as keyboard wedge, RS232 serial, and the latest USB interface. You will need to select an appropriate model for a specific interface. Interface selection: The factory interface default can not be changed for other type interface. One specific model only supports the appropriate host interface.
Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: AS-8000 keyboard wedge model only supports keyboard interface with PS/2 type connector.
Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard” to select country at “language” item. For details, please refer to your DOS or WINDOWS user’s manual. Keyboard Speed: By selecting, you can change output speed of scanner to match with host computer.
Keyboard layout Keyboard speed USA 00 Belgium 01 Danish 02 France 03 Germany 04 Italian 05 Portuguese 06 Spanish 07 Swedish 08 Switzerland 09 UK 10 Latin American 11 Japanese 12 0-8 00-08 0 : high clock rate 03 8 : low clock rate Disable 00 Enable 01 Alphabetic key 00 Numeric keypad 01 Function key Numeric key (Num lock state only) Alt+Keypad 11 02 Exit
Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on. Inter-character delay: This delay is inserted after each data characters transmitted.
Program Option Bar Code Option Alphanumeric Entry Caps lock”ON” 00 Caps lock”OFF” 01 Disable 00 Enable 01 00-99 msec 00-99 Caps lock Power-on simulation 02 Inter-character delay 00-99 10 msec 00-99 10 Block transmission delay Exit 13
RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII Code13 16) Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol. RTS/CTS-If the scanner wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication.
Program Option Bar Code Option Alphanumeric Entry Flow control None 00 RTS/CTS 01 Xon/Xoff 02 ACK/NAK 03 00-99 (msec) 00-99 00 Inter-character delay 00-99 (10 msec) 00-99 00 Block transmission delay 00-99 (100 msec) 00-99 20 Response delay Exit 15
Program Option Bar Code Option Alphanumeric Entry Baud rate Parity 300 BPS 00 600 BPS 01 1200 BPS 02 2400 BPS 03 4800 BPS 04 9600 BPS 05 19200 BPS 06 38400 BPS 07 None 00 Odd 01 Even 02 8 bits 00 7 bits 01 One bit 00 Two bits 01 Data bit Stop bit Exit 16
Pin Assignments Keyboard Wedge Connector (To Host Side): Pin Mini-DIN 6P Male Mini-DIN 6P Female 1 DATA / PC CLK / KB 2 NC GND 3 GND DATA / KB 4 VCC (+5V) VCC (+5V) 5 CLK / PC NC 6 NC NA 4 6 3 5 2 1 Mini-DIN 6P Female Connector Mini-DIN 6P Male Connector 6 4 5 3 2 1 RS-232 DB-9F Connector (To Host Side): Pin Definition 1 NC 2 TXD 3 RXD 4 NC 5 GND 6 NC 7 CTS 8 RTS 9 VCC (+5V) 17 5 4 3 2 1 9 8 7 6
Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the scanner will beep buzzer to indicate a good barcode reading, and its Beep loudness, Beep tone freq. and Beep tone duration are adjustable. Beep loudness/Beep tone freq.
Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01 Disable 00 Enable 01 Disable 00 Enable 01 00-07 00-07 Power on alert LED indication Beeper indication 07 Beep loudness 00-99 (100Hz) 00-99 27 Beep tone freq.
Transmission Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, Postamble will be appended after the data is transmitted. Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is “00” to indicate no character insertion. Beside, make sure insertion positions are not greater than the symbols; otherwise the insertion data is not effective.
00-63 00-63 (00: no insertion) 00 00-63 00-63 (00: no insertion) 00 00-63 00-63 (00: no insertion) 00 00-63 00-63 (00: no insertion) 00 Before code data 00 After code data 01 Insert data group 1 position Insert data group 2 position Insert data group 3 position Insert data group 4 position Code ID position Exit 21
Transmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected. The total length of the barcode is the number of barcode data except Truncate Leading/Ending Digits. And the length is a number with two digits.
Disable 00 Enable 01 Disable 00 Enable 01 Disable 00 Upper case 01 Lower case 02 Code length transmission Code name transmission Case conversion *For barcode data only Exit Format of barcode data transmission: Prefix Name Preamble ID Code Barcode Length data Insert groups 23 ID Postamble Suffix
Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate-The trigger button acts as a toggle switch. Press button to activate or stop scanning.
Scanning mode Good-read off 00 Momentary 01 Alternate 02 Timeout off 03 Continue 04 Test only 05 01-99 (second) 01-99 06 Stand-by duration 01-99 (10 msec) 01-99 50 Double read timeout Double confirm 00-99 00-09 (00: no double 00 confirm) 00-40 00-40 20 Supplement Check Counter Exit 25
Scan Global min./max. code length: Global Minimum and Maximum length can be set to qualify data entry. The length is defined as the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise the labels of the symbology will not be readable. In particular, you can set the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded.
Program Option Bar Code Option Alphanumeric Entry 00-64 00-64 04 Global min. code length 00-64 00-64 63 Global max.
28
String Setting Prefix characters: Up to 22 ASCII characters may be sent before data digits. Prefix Data Digits Suffix Suffix characters: Up to 22 ASCII characters may be sent after data digits.
String Setting Preamble/ Postamble characters: They are appended to the data automatically when each barcode is decoded. Example: Add a prefix/suffix or preamble/postamble for all symbologies. In this example, you are sending a $ symbol as a prefix for all symbologies. Steps: 1) Scan Programming and Prefix characters setting barcode. 2) Use the ASCII code table to find the value of $ 24. 3) Scan 2 and 4 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page.
Program Option Bar Code Option Alphanumeric Entry Preamble characters Postamble None ‘PREAMBLE’ 1-22 00-ffH ASCII characters code None ‘POSTAMBLE’ 1-22 00-ffH ASCII characters code None ‘GROUP1’ 1-22 00-ffH ASCII characters code None ‘GROUP2’ 1-22 00-ffH ASCII characters code None ‘GROUP3’ 1-22 00-ffH ASCII characters code None ‘GROUP4’ 1-22 00-ffH ASCII characters code characters Insert G1 characters Insert G2 characters Insert G3 characters Insert G4 char
UPCA Read: Format Leading Zero Data Digits (11 Digits) Check Digit Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. It will beep instead of reading anything when the truncate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of the Ending. The maximum value of truncate digits is 15.
Disable 00 Enable 01 0-15 00-15 Check-sum transmission 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code < A > 00-44 00-44 Code ID setting 00 Insert group selection Exit 33
UPCA Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters for WPC code. Format Leading Data Digits Check Zero (11 Digits) Digit Supplement Digits 2 or 5 or UCC / EAN 128 Truncation / Expansion: The leading “0” digits of UPCA data characters can be truncated when enabled. Supplement Check Counter: It will be more reliable to read the barcode with extension (supplement) like UPCE/A or EAN-8/13, but slow down the decoding speed when this counter is set more.
None 00 Truncate leading 01 Truncation/ zero Expansion Expand to EAN13 02 20 Supplement Check Counter The Exit 35
UPCE Read: Format Leading Zero Data Digits (6 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
0-15 00-15 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code < E > Code ID setting Exit 37
UPCE Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Leading Zero Data Digits Check (6 Digits) Digit Supplement Digits 2 or 5 or UCC/EAN 128 Expansion: The expansion function is used only for UPCE and EAN-8 code reading. It extends to 13-digits with “0” digits when the feature is enabled.
Supplement digits Truncation/Expansion None 00 2 digits 01 5 digits 02 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 128 05 5, UCC/EAN 128 06 All 07 None 00 Truncate leading 01 zero Expand to EAN13 02 Expand to UPCA 03 Disable 00 Enable 01 Disable 00 Enable 01 Expansion *OAM* UPCE-1 20 Supplement Check Counter Exit 39
EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
0-15 00-15 00 Truncate ending Exit 41
EAN-13 Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Data Digits (12 Digits) Check Digits Supplement Digits 2 or 5 or UCC / EAN 128 ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two kinds of barcode for book and magazines. The ISBN is 10 digits with leading “978” and the ISSN is 8 digits with leading “977” of the “EAN-13” symbology.
00-ffH ASCII 00-ffH code < F > 00-44 00-44 Code ID setting 00 Insert group selection Supplement digits None 00 2 digits 01 5 digits 02 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 128 05 5, UCC/EAN 128 06 All 07 Disable 00 Enable 01 ISBN/ISSN conversion 20 Supplement Check Counter Exit 43
EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check-sum verification: The checksum of EAN-8 is optional and made as the sum of the numerical value of the data digits. Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
0-15 00-15 00 Truncate leading 0-15 00-15 00 Truncate ending Code ID setting Two characters 00-ffH, 00-ffH 00-ffH ASCII < FF > code 00-44 00-44 00 Insert group selection Exit 45
EAN-8 Supplement digits: Format Data Digits (7 Digits) Check Digits Supplement Digits 2 or 5 or UCC/EAN 128 Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE. Supplement Check Counter: It will be more reliable to read the barcode with extension (supplement) like UPCE/A or EAN-8/13, but slow down the decoding speed when this counter is set more.
Disable 00 Enable 01 None 00 Truncate leading 01 Truncation / Expansion Truncation / zero Expansion Expand to EAN13 02 Disable 00 Enable 01 Expansion Exit 47
Code 39 Read: Format Start “ ” Data Digits ( Variable) Checksum (Optional) End “ ” Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect.
Disable 00 Enable 01 Disable 00 Enable 01 00-64 00-64 Check-sum verification Check-sum transmission 00 Max. code length 00-64 00-64 01 Min.
Code 39 Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z). Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embedded appending code (space for Code-39).
Standard 00 Full ASCII 01 Disable 00 Enable 01 Disable 00 Enable 01 Format Append Start/end transmission Exit 51
Interleaved 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01 00-64 00-64 Check-sum transmission 00 Max. code leading 00-64 00-64 00 Min.
Industrial 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01 00-64 00-64 Read 00 Max. code length 00-64 00-64 00 Min.
0-15 00-15 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code < i > 00-44 00-44 Code ID setting 00 Insert group selection Exit 55
Matrix 2 of 5 Eur Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01 Checksum Transmission 00-64 00-64 00 Max. code length 00-64 00-64 00 Min.
Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01 00-64 00-64 Checksum Transmission 00 Max. code length 00-64 00-64 00 Min.
Codabar Insertion group selection: Refer to Insertion group selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39.
Code-128 Read: Format Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character. The first FNC1 will be translated to “]C1”,and next to be a field separator code as (1D16).
0-15 00-15 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code < # > 00-44 00-44 Code ID setting 00 Insert group selection Standard 00 UCC/EAN-128 01 Format Exit 63
Code-128 Append: When the function is enabled, it won' t show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn' t have FNC2 code. UCC/ EAN 128 ID setting: To setting the code ID for UCC/EAN-128 output format. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you can reassign second or after a FNC1 for your usage. The default of ASCII code is (1D16).
Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00-64 00-64 00 Max. code length 00-64 00-64 00 Min.
00-ffH ASCII 00-ffH code < & > 00-44 00-44 Code ID setting 00 Insert group selection Exit 67
Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01 00-64 00-64 Checksum Transmission 00 Max. code length 00-64 00-64 00 Min.
MSI/Plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max.
Disable 00 Enable 01 00-64 00-64 Checksum Transmission 00 Max. code length 00-64 00-64 00 Min.
UK/Plessey Read: Format Data Digits (Variable) Checksum1+2 (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01 00-64 00-64 Checksum Transmission 00 Max. code length 00-64 00-64 00 Min.
Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
00-64 00-64 00 Max. code length 00-64 00-64 00 Min.
Standard 2 of 5 Read: Format Data Digits (Variable) Checksum1 (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
*JAC* Disable 00 Enable 01 00-64 00-64 Check-sum transmission 00 Max. code length 00-64 00-64 00 Min.
GS1 DataBar Omnidirectional Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. UCC/EAN 128 emulation: Refer to Transmission, Code ID transmission must be set as AIM ID enable. Then ]C1 will be identified as prefix of barcode data transmission.
Code ID setting 00-44 00-44 00 Insert group selection Disable 00 Enable 01 UCC/EAN128 emulation Exit 79
GS1 DataBar Limited Read: Format Data Digits (Variable) Checksum1 (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of GS1 DATABAR OMNIDIRECTIONAL.
00-ffH ASCII 00-ffH code < RL > 00-44 00-44 Code ID setting 00 Insert group selection Disable 00 Enable 01 UCC/EAN128 emulation Exit 81
GS1 DataBar Expanded Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of GS1 DATABAR OMNIDIRECTIONAL.
00-99 00-99 01 Min.
China Post Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01 00-64 00-64 Read 11 Max. code length 00-64 00-64 11 Min.
0-15 00-15 00 Truncate leading 0-15 00-15 00 Truncate ending 00-ffH ASCII 00-ffH code < t > 00-44 01-44 Code ID setting 00 Insert group selection Exit 85
Italian Pharmacode Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Leading “A”: If this function is enabled, each prefix of data shall be A.
00-64 00-64 09 Min.
CODABAR-PARA CODE-11 PARA CODE-128 PARA CODE-39 PARA CODE-93 PARA EAN-13 PARA 88
STANDRAD-25 PARA EAN-8 PARA INDUSTRIAL-25 PARA UPCE PARA INTERLEAVED-25 PARA 89
MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA UK/PLESSEY PARA GS1 DATABAR OMNIDIRECTIONAL 90
ASCII Code Table " # $ (& ' ) ) *.+27 859 " = > ? A(B C DE? I C!*(I C!+(9 $ % 6 < @ H N R T : W X V K #27 [\= ,F9 _ ,F9E?`=ba d 9 T = a ? +2= ) = ?h= R 4 + , / " # $ % 6 < @ H N Q S V K R 4 + , / 6 0 I k m n o p q s u w y g % / % /6 / < /@ /H /N / Q /S /V /F%Z$ , TE] /F% % /F% 6 42?eaf) g KG) ?eg Q S ! $ % & * " +(" , 0213# +245% 0 : ; +24 6 , : ; +24 < ,F1G: +242@ ,2&.
Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your AS-8000 scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code.
Firmware version list If you wish to display the firmware version, scan the Firmware version list. WARNING: Default value initialization If you wish to return the AS-8000 scanner to all the factory default settings, scan the Default value initialization bar code.
0 A 1 B 2 C 3 D 4 E 5 F 6 7 8 Finish 9 94