H200 & H200HF SERIES WATER CONDITIONERS H200 Top Mount H200 Side Mount H200HF Side Mount For Commercial & Industrial Applications Apartment Buildings Boiler Water Treatment Car Washes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home Parks Motels and Hotels Nursing and Rest Homes Office Buildings Restaurants Schools
Hellenbrand Means Quality and Reliability Since 1967, Hellenbrand, Inc. has provided water solutions to the water treatment industry in the U.S. and around the world. Our growth in the water treatment industry is a direct result of providing high quality products and supporting the applications for those products with over 200+ years of industry knowledge before, during and after the sale, which has resulted in multiple applications over the years with the same customers.
The H200 / H200HF is powerful, easy to use and packed with benefits • • • • • • • • • • • • • Solid state microprocessor can control from one to four units allowing you system add on capabilities as your needs grow. Regeneration may be initiated with a time clock, meter delayed or meter immediate. Up to nine fully programmable cycle times, that can be moved around and repeated in various orders for your particular application needs.
H200/H200HF Diagnostic and History Screens provide the water treatment operator with a wealth of information. Page 20 WS2H Control Valve Manual Diagnostic Screens Returns to normal operation after 5 minutes. Accessed by pressing UP and DOWN simultaneously for >3 seconds. Diagnostic Screens All Diagnostic History screens are resettable • Days since last regeneration with the Historytreated Reset sequence whileregeneration in the • Total volume since last Diagnostics1 screen.
H200/H200HF Diagnostic and History Screens provide the water treatment operator with a wealth of information. WS2H Control Valve Manual Page 21 Diagnostic Screens (continued) DIAGNOSTIC 5 Max flow rate of the day DIAGNOSTICS 5 Maximum flow rate for the last 28 days. Automatically Toggles Simultaneously press UP and DOWN. DIAGNOSTIC 5-B DIAGNOSTICS 5-B Hourly history of maximum flow rate. Use the UP and DOWN arrow to select the hours of the day from screen 5.
H200/H200HF Diagnostic and History Screens provide the water treatment operator with a wealth of information. Page 22 Valve History Screens • Total days in operation • Total regenerations since start-up • Total volume of treated water WS2H Control Valve Manual Valve History Returns to normal operation after 5 minutes. Non-Resettable Accessed by pressing UP and DOWN simultaneously for >3 seconds, then by pressing UP and DOWN simultaneously again for >3 seconds.
Modes of Regeneration Time Clock - 7 or 28 day calendar clock shall initiate regeneration at a pre-set time of day. Parallel Individual Meters - All units are in service at the same time with either delayed or immediate regeneration. A lockout feature or offsetting time of regeneration prevents more than one unit to regenerate at a time. Units may use either a fixed or variable reserve for operation.
H200 Series A A. MINERAL TANK: Fiberglass tank with Polyethylene Inner B. C. D. E. F. G. Shell and Fiberglass Roving Manufactured to Operate at 150 psi. NSF Approved. DISTRIBUTOR SYSTEM: Two-Inch Hub & Lateral Distributor for Maximum Service Flow and Minimal Pressure Loss. MINERAL: High Capacity Ion Exchange Resin. Uniform and stable beads assure long life, high salt efficiency, and maximum hardness removal.
H200 Twin/Triplex/Fourplex Installation Top-Mount First-in, Last-Out Piping Arrangement. "MAV" Shown for demand recall. Four Plex shown for reference only. Bypass Valve Shut-Off Valve Inlet Outlet Isolation Valves Shut-Off Valve Brine Tank(s) Brine Tank(s) MAV Valve Flex Connectors Figure 4 See NOTE Figure 5 MAV = Motorized Alternating Valve. H200 Single Installation - Side Mount Bypass Valve Sidemount Adapter Base Inlet 2” FNPT Inlet & 2.
H200 Twin Alternating - Side Mount Bypass Valve MAV Valve Outlet Inlet Shut-Off Valve Isolation Valves Brine Tank Figure 6 See NOTE Figure 7 MAV = Motorized Alternating Valve. H200 Twin/Triplex/Fourplex Installation - Side Mount First-in, Last-Out Piping Arrangement.
H200 HF Single Tank Installation High Flow Service Valve Pipe is on an angle Isolation Valve Inlet Outlet is Plugged Bypass Valve Brine Tank Outlet Meter High Flow Service Valve1 See NOTE Figure 7 Figure 8 Air or water operated 1 H200 HF Twin Alternating Installation High Flow Service Valve Inlet Valve outlet is plugged Pipe is on an angle DLFC DLFC Meter Brine Tank Outlet Figure 9 See NOTE Figure 7 High Flow Service Valve1 Air or water operated 1 H200 HF Triplex/Fourplex Installation
H200 Physical Specifications Mineral tank sizes shown are with polyglass tanks.
H200HF Physical Specifications Mineral tank sizes shown are with polyglass tanks.