Datasheet
www.argoclima.com
Technical specifi cations
27
Catalytic and infrared heaters
Balanced fl ow gas radiators
44RQ INFRA 42C LYRA 4000
VTQ
LYRA 3000
VTQ
LYRA 3000
SQ
Heat output W 2270/2600/3050 1200/2800/4000 4000 3060 3060
Maximum heating capacity W
Max. heating volume m
3
95 120 150 110 100
Portable unit •••• •
Flue pipe diameter mm 120 120 120
Piezoelectric ignition •••• •
Pilot fl ame • •
Manual heat output adjustment • •
Thermostat modulating the fl ow of gas to the burner •• •
Airtight combustion chamber in cast iron •• •
Heating type Radiation Radiation Convection Convection Convection
Forced ventilation ••
Tangential fan ••
Fan speeds no. 1 1
Methane gas consumption m
3
/h 0.400 0.310 0.310
LPG consumption g/h 142/177/210 98/195/292 289 222 222
Power supply voltage V/F/Hz 230/1/50 230/1/50 230/1/50
Carbon dioxide monitoring device • •
Device protecting the pilot fl ame from being extinguished •
Overturn protection device •
Dimensions (H./W./D.) mm 805/425/445 740/420/360 490/710/205 490/590/205 490/590/205
Weight kg 18 9 40 30 30
Gas heaters
VENTOSOLE
316 ASQ-A
VENTOSOLE
246 ASQ
THERMOSOLE
2.98 ASQ
THERMOSOLE
2.78 ASQ
THERMOSOLE
1.62 ASQ
Heat output W 9100 8500 7600 6900 5300
Maximum heating capacity W 11000 10300 9200 8450 6500
Max. heating volume m
3
400 380 270 250 200
Fixed wall/fl oor installation • • • • •
Porcelain enamel paint fi red at 900°C • • • • •
Flue pipe diameter mm 80/100 80 80 80 80
Electronic ignition •
Piezoelectric ignition ••••
Pilot fl ame ••••
Manual power adjustment •
Thermostat modulating the fl ow of gas • • • •
Forced ventilation • •
Fan speeds no. 2 1
Methane gas consumption m
3
/h 1.164 1.090 0.940 0.860 0.690
LPG consumption g/h 697 641 630 610 497
Power supply voltage V/F/Hz 230/1/50 230/1/50
Fume discharge monitoring device •••••
Dimensions (H./W./D.) mm 695/830/270 760/720/250 710/660/240 645/600/240 580/440/240
Weight kg 38 35 27 23 13