Operating instructions
11
V 12/14
CONTROL PANEL
1. ON/OFF BUTTON Press this button to turn the dehumidifier on and off.
2. FILTER BUTTON
: After 250 hours of operation, the FILTER RESET led turns on to indicate that it is time to clean
the filter. Take the filter out and clean it. Then press the FILTER button.
3. RELATIVE HUMIDITY ADJUSTER BUTTONS
: The humidity can be set from 35% to 80% in 5% steps with the + and -
buttons, or you can set the appliance to continuous drain (CO) – maximum dehumidification.
4. DISPLAY
: Shows the relative humidity setting.
5. FAN SPEED BUTTON Press these buttons to set the fan speed (LOW / MID / HIGH).
6. TIMER ON/OFF BUTTON: Delayed on/off button (2 or 4 hour delay).
TIMER LED: shows the timer setting (2 or 4 hours).
HIGH/MID/LOW FAN SPEED LED: Shows the fan speed: HIGH, MID or LOW.
TANK FULL LED: When the tank is full, the TANK FULL LED comes on and the appliance stops running. A 10
second beep sounds. Remove the tank and empty it (as indicated in "HOW TO ELIMINATE CONDENSATION"),
the restore it; the dehumidifier will start running again.
STAND BY LED
CONTINUOUS LED: Shows that the dehumidifier is running in continuous mode.
FILTER RESET LED: indicates that the filter must be cleaned.
DEFROST: The dehumidifier is designed to operate at ambient temperatures from + 5°C to + 35°C.
If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.
When this happens, the dehumidifier goes into defrost mode. The compressor stops, but the fan continues
running.
We recommend not using the dehumidifier in room temperatures lower than 5°C.
AUTO RESTART: The dehumidifier starts up again after a power failure.
MEMORY FUNCTION: The dehumidifier maintains its settings during a power failure.
CLEANING AND MAINTENANCE
MAINTENANCE OF THE HUMIDIFIER’S EXTERIOR SURFACE
Warning
Always pull the dehumidifier's plug out of the power socket before cleaning it, to prevent electric
shock and malfunction.
Warning
Do not wet the appliance or immerse it in water, otherwise electric shocks may occur.
TANK FULL
LED
TIMER LED
STAND-BY LED
CONTINUOUS
OPERATION
CLEAN
FILTER
LED
LOW-MEDIUM-HIGH FAN
SPEED LED