Service manual

46
AVOID:
heat sources, exhaust fans, etc. (Fig. 3)
damp, humid or uneven locations.
DO:
choose a place as cool as possible.
choose a place that is well ventilated.
allow enough room around the unit for air
intake/exhaust and possible maintenance.
(Figs. 4a to 4c)
provide a solid base (concrete block, 10
40 cm
beams or equal), a minimum of 10 cm above ground
level to reduce humidity and protect the unit against
possible water damage and decreased service life.
(Fig.5a and 5b)
use lug bolts or equal to bolt down unit, reducing
vibration and noise.
Outdoor Unit
Outdoor unit
Hot air
Heat source
Exhaust fan
Fig. 3
Fig. 3
Air intake
Min. 10 cm
Air discharge
Min.
5 cm
Min.
40 cm
Valve
side
Min. 25 cm
Top View
Air intake
Concrete
or equal
About 10 cm
Min. 10 cm
Anchor bolts
(4 pcs.)
About 40 cm
Fig. 5 - A
Ground
Obstacle
Obstacle above
Air discharge
Fig 4 C
Min.
2 m
Min.
2 m
Side View
Fig. 4c
Required space around the unit.
Top View
Fig. 4a
Fig. 5a
Fig. 5 - B
Min. 10 cm
Anchor bolts
(4 pcs.)
Fig. 5b
Min. 10 cm
Air discharge
Min.
10 cm
Min.
50 cm
Valve
side
Min. 60 cm
Fig 4 B
Air intake
Top View
Fig. 4b
AER518SCL3 mod.
AER522SCL3 mod.
AER518/522SCL3 mod.
AER518SCL3 mod.
AER522SCL3 mod.