Service manual
13
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Part No. POW–K185GS–N
Controls Microprocessor
Control circuit fuse 250 V – 3 A
Remote Control Unit RCS – 5PN3E
Type Centrifugal
Number ... Dia. and length mm 2 ... ø 130 / L 180
Fan motor model ... Number K48410–M01418 ... 1
No. of poles ... rpm (230 V, High) 4 ... 1,280
Nominal output W 41
Coil resistance (Ambient temp. 20°C) Ω GRY – WHT : 95 ±7%
WHT – VLT : 73 ± 7%
VLT – YEL : 73 ± 7%
WHT – PNK : 207 ± 7%
Safety
Type Internal thermal fuse
devices
Operating temp.
Open °C 145 ± 5
Close Automatic reclosing
Run capacitor
µF 2.0
VAC 440
Model M2LJ24ZE31
Rating AC 208 / 230 V, 50 / 60 Hz
No. of poles ... rpm 8 ... 2.5 / 3.0
Nominal output W 3 / 2.5
Coil resistance (Ambient temp. 20°C) kΩ 16.45 ± 15%
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.8
Face area m
2
0.192
Heat
Exch. Coil
Flap Motor Fan & Fan Motor
Controller
PCB
Indoor Unit FCR522CL