14 NIGHT Function
When this setting is active indoor fan speed is automatically reduced in order to allow low noise
operation.Temperature control acts in the same way as NORMAL MODE but after 60 minutes
of operation the air conditioner modifies automatically the set-point temperature according to the
following:
•COOLING/DRY: +1°C
•HEATING: - 2°C
15 LED OFF function
This is a special function mode which can be selected by the user. With this option active
the OPERATION, TIMER and STANDBY lamps are switched off even during operation
(they activates only in case of diagnostic signaling)
.
Before setting this mode, ensure that the icon 'FILTER' is not shown on display of remote controlle
r
and pressing, at the same for more than 5 seconds the IFEEL and FAN buttons
To reset the normal lamps signaling, press at the same for more than 5 seconds the
IFEEL and FAN buttons
16 Capacity Test mode
This is a special operating mode used when testing the performance of the A/C. In this case the main
components of the A/C (compressor , outdoor fan, indoor fan) operate at fixed settings.
This option is activated by setting the remote controller as follows:
-select filter on
-select high power on
-set the mode and temperature based on which kind of test is needed
COOLING MODE: Setpoint = 10°C
HEATING MODE: Setpoint = 32°C
- press at the same time for more than 5 seconds IFEEL and FAN buttons
In cooling capacity test mode the TIMER lamp blinks while the OPERATION lamp is on
In heating capacity test mode the TIMER lamp blinks while the STANDBY lamp is on
To reset the unit to normal mode, just turn off the power supply of the unit for at least 1 minute.