EN DEHUMIDIFIER OPERATING INSTRUCTIONS Read the instructions carefully before operating or servicing the dehumidifier. Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage. Keep these instructions in a safe place for future reference.
GENERAL OPERATING AND SAFETY INSTRUCTIONS This appliance is a highly efficient dehumidifier, designed for domestic use only! Use this dehumidifier only as outlined in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or malfunctions. The unit contains refrigerant; keep it vertical at all times. Once you have opened the unit, keep it vertical to allow the refrigerant to stabilise and wait two hours before operating it.
can cause fires or electric shocks. If the power cord is damaged, it must be replaced by a service centre. Do not place heavy objects on top of the appliance. To prevent water spills, empty the water tank before moving the appliance. Do not tilt the dehumidifier onto one side or turn it upside down, as the water which runs out could damage the appliance. Do not operate the unit on unstable or sloping surfaces: water leaks can cause it to malfunction or cause excessive vibration and running noise.
DESCRIPTION OF PARTS FRONT VIEW (1) (2) (3) (4) REAR VIEW (5) 1) CONTROL PANEL 2) DEHUMIDIFIED AIR OUTLET 3) CONTINUOUS CONDENSATION DRAINAGE HOLE COVER 4) AIR INTAKE 5) POWER CORD ATTACHMENT HOLE 6) CONDENSATION COLLECTION TANK 7) POWER CORD (6) (7) CHECKS BEFORE START UP Check that the float and the condensation collection tank are correctly positioned 1. Remove the tank using both hands and following the direction of the arrow.
2. Check the position of the float inside the tank; it may have shifted during the move. If it is not positioned correctly, reposition it before using it. Float Incorrect position 3. Correct position Then, reposition the tank. OPERATING INSTRUCTIONS APPLIANCE START-UP Place the product on a flat and stable heat-resistant surface, at least 1 metre away from flammable or heat-sensitive materials and 50 cm away from walls or other obstructions. Make sure the water tank is in the correct position.
REMOVING THE CONDENSATION - FILLING THE INNER TANK The water extracted from the air can be collected in the rear tank. When the tank is full, the unit turns off. The FULL TANK led turns on and the unit beeps for about 10 seconds. To switch off the appliance, press the ON/OFF button and wait a few seconds. 1. Carefully remove the tank using both hands and following the direction of the arrow. 2. Empty the tank. 3. Reposition the tank following the direction of the arrow. (1) (2) (3) N.B.
CONTROL PANEL TANK FULL LED DEFLECTOR POSITION LED FILTER RESET LED AIR FLOW DIRECTION SETTING BUTTONS DEHUMIDIFICATION MODE LED TIMER LED DISPLAY (6) (5) DEHUMIDIFICATION MODE SELECTION: - SMART - CONTINUOUS - QUIET - DRY (4) HUMIDITY SETTING HIGH-MEDIUM-LOW FAN SPEED LED (3) (2) TIMER FAN (1) ON/OFF BUTTON (1) ON/OFF BUTTON: press to turn the dehumidifier on and off. (2) FAN BUTTON: press to adjust the fan speed: High, Med, Low.
AUTO-STOP: automatic shut-down of the unit if the tank is full or incorrectly positioned, or when the room humidity is 5% below the set humidity. AUTO RESTART: the dehumidifier starts up again after a power failure. MEMORY FUNCTION: the dehumidifier maintains its settings during a power failure. CHILD LOCK: to disable the buttons, press the Mode and Timer BUTTONS for 1 second: the LC symbol will appear on the display. To reactivate the control panel, press the Mode and Timer buttons again for 1 second.
CLEANING THE AIR FILTER The filter is designed to remove dust or dirt from the air. If the filter is clogged by dust, electricity consumption will be higher than normal. To optimise humidity removal efficiency, clean the filter when the FILTER CLEAN LED turns on. Cleaning instructions: 1. Press the side levers and slightly separate the front panel from the bottom, then the top. 2. Remove the filter by pulling the top towards you.
TROUBLESHOOTING POTENTIAL CAUSE PROBLEM The dehumidifier is not working. The temperature is above 35 ° C or below 5 It is not possible to adjust the settings. °C. SOLUTION The internal tank is full. Empty the tank The tank is not positioned correctly. Position the tank correctly The set humidity level is higher than that in the room. The noise suddenly increases while The compressor has just started. running There is a power connection problem. The unit is placed on an uneven surface.
REGULATION (EU) No. 517/2014 - F-GAS PLATINUM 21 The unit contains R134A, a fluorinated greenhouse gas with global warming potential (GWP) = 1430 - Kg. 0.185 = 0.265 Tons CO2 equiv. Do not release R-134a into the atmosphere. PLATINUM 41 The unit contains R410A, a fluorinated greenhouse gas with global warming potential (GWP) = 2087.5 - Kg. 0.310 = 0.647 Tons CO2 equiv.