EN PORTABLE AIR CONDITIONER (LOCAL) OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage. Store these instructions in a safe place for future reference.
GENERAL OPERATING AND SAFETY INSTRUCTIONS This appliance is a portable air conditioner designed for domestic use. Only use this air conditioner as described in this manual. Ensure that the required voltage and frequency (220-240V / 50Hz) match the available power source.
Do not install the air conditioner in rooms that may be subject to water spray (e.g. laundries). This air conditioner can be used by children of 8 years or older and by persons with reduced physical, sensory and mental abilities, or lacking the necessary experience and knowledge, provided they are supervised or instructed on its use by a person responsible for their safety, so that they are fully aware of the attendant risks.
Please wait at least 3 minutes before starting the unit. This helps prevent the compressor from being damaged. WARNING! In the event of an anomaly, switch the appliance off and unplug it from the socket. Do not dismantle or attempt to repair or modify the product. In the event of a malfunction, contact the service centre directly.
DESCRIPTION OF THE APPLIANCE FRONT VIEW 1) HANDLES 2) AIR OUTLET 3) CONTROL PANEL - BUTTONS FOR OPERATION WITHOUT REMOTE CONTROL 4) SIGNAL RECEIVER 5) FINS AND AIR FLOW OUTLET 6) FRONT 7) AIR INTAKE 8) CORD WINDING HOOK 9) DRAINAGE HOLE FOR DEHUMIDIFICATION FUNCTION 10) AIR INTAKE 11) DRAINAGE HOLE FOR COOLING FUNCTION 12) HANDLES 13) AIR OUTLET AND FITTING REAR VIEW 14) POWER CORD OUTLET 15) SWIVEL CASTERS 16) REMOTE CONTROL 1 (16) Min/max operating limits (internal temperature) Coolin
APPLIANCE START-UP Open the packaging and pull out the box. Remove the product and the other elements supplied (illustrated in the box below). Infrared remote control + button battery type (CR2032/3V) Fitting (1) for positioning between the air discharge outlet and the flexible pipe. Window unit kit with plug. Flexible pipe. Round fitting for window unit, for positioning between the end of the tube and the window unit itself. End fitting for window (2). Drainage tube (continuous drainage).
The drainage tube can be compressed to minimum 450 mm and extended to maximum 1500 mm. It is advisable to keep the tube compressed to the minimum. Rest the terminal connector against the fixed section of the window and move the other section up towards it. 5. Avoid tight bends and folds in the flexible pipe. USE WITH WINDOW UNIT KIT 1. Make a hole having a diameter of roughly 133 mm on the glass window. 3.
HOW TO USE THE APPLIANCE This appliance can be used for cooling, dehumidifying and ventilation purposes. When switching between modes, the fan continues operating but the compressor stops: the compressor will start again 3 minutes later. This delay protects the compressor from potential damage.
During dehumidification, continuous drainage should be implemented (see the next chapter, “HOW TO ELIMINATE CONDENSATE”). 3. FAN ONLY MODE Press the MODE button until the Fan icon displays. In this mode, the fan speed can be set. The temperature cannot be regulated. HOW TO ELIMINATE CONDENSATE Cooling This appliance automatically vaporises condensate in the cooling mode.
REMOTE CONTROL OPERATION 1. Slide to open the cover according to the direction indicated by the arrowhead. 2. Insert the batteries (CR2032/3V) into the remote control and make sure the poles match. 3. Put back the cover. 4. Aim the remote control towards the receiver on the airconditioner. 5. The remote control should be within 8 meters away from the receiver. 6. No obstacles between the remote control and the receiver. 7. Do not drop or throw the remote control. 8.
FOR OPTIMAL REMOTE CONTROL OPERATION, POINT THE TRANSMITTER HEAD TOWARDS THE RECEIVER ON THE AIR CONDITIONER. 2 3 SPEED 4 SWING TIMER ON/ OFF 1 SLEEP + DRY COOLFAN 10 9 - 5 6 7 HEAT 8 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. ON/OFF BUTTON SPEED BUTTON SWING BUTTON TIMER BUTTON (LCD ON/OFF) SLEEP BUTTON “+” AND “-“ BUTTON FAN BUTTON HEAT BUTTON COOL BUTTON DRY BUTTON (1) “ON/OFF” BUTTON Press the ON/OFF button to turn on or off the air conditioner.
(7) “FAN” BUTTON Press “FAN” to start the Ventilation mode. (8) “HEAT” BUTTON Press “HEAT” to start the heating mode. (9) “COOL” BUTTON Press “COOL” to start the refrigeration mode. (10) “DRY” BUTTON Press “DRY” to start the dehumidification mode. Note: Only when temperature reaches 16°C can we turn on the dehumidification mode, besides, the drain pipe must be installed. CARE AND MAINTENANCE WARNING! Before carrying out any cleaning or maintenance operations, unplug the appliance. 1.
2. Cleaning the casing. Use a damp and soft cloth to clean the outer surface of the appliance. Do not use excessively hot water, solvents, petrol or other aggressive chemical compounds, talcum powder or brushes: these may damage the surface or colour of the casing. Remove any stains using lukewarm water with a little neutral detergent. Do not pour water onto the air conditioner to clean it, as this may damage its internal components or cause a short-circuit. 3. Storage.