Datasheet
1 unit
JUNO DCI 09 UI D
JUNO DCI 12 UI D
2 units
JUNO DCI 09 UI D X 2
JUNO DCI 09 UI D +
JUNO DCI 12 UI D
www.argoclima.com
JUNO
DCI DUAL
33
e technical data provided refers to European Standard EN14511, as per Directive 2002/31/CE
596 mm
899 mm
D C I
ON-OFF
Unit of
measurement
JUNO DCI OU D
COOLING HEATING
Indoor units operating simultaneously N° 2
Capacity - nominal (min-max)
kW 5.0 (2.05-6.2) 5.6 (2.5-6.65)
BTU/h 17000 (7000-21150) 19100 (8600-22700)
Energy Label ABCDEFG A A
E.E.R. / C.O.P. (kW/kW) 3.23 3.64
O.U. air flow rate m3/h 2600-2300-1600
O.U. fan speed N° 3
Sound pressure O.U. (h.-m.-l.) dB(A) 56-53-50
Electrical power supply V/Ph/Hz 230/1/50
Power input - nominal (min-max) kW 1.55 (0.5-2.55)
Annual energy consumption in cooling mode - Dir. 2002/31/CE
kWh 775 (250-1275)
Compressor type Twin Rotary (DC inverter)
Type of refrigerant R410A
Liquid pipe diameter mm (") 6.35 (1/4")
Gas pipe diameter mm (") 9.52 (3/8")
Maximum length of pipes per unit m 10
Maximum total length of pipes m 20
Pipe lenght with standard charge - total m 10 (5+5)
Maximum height difference (outdoor unit above) m 5
Maximum height difference (indoor unit above) m 5
Net weight O.U. Kg 43
Net dimensions O.U. (H./W./D.) mm 596x899x378
A single outdoor unit is enough to control the climate in 2 rooms, small or
large it doesn't matter... With the performance, efficiency and quietness
that only DC Inverter technology can provide.
UOM JUNO DCI 9 IU D JUNO DCI 12 IU D
COOLING HEATING COOLING HEATING
Capacity kW 2.60 2.80 3.5 3.8
Air flow rate m³/h 500 630
Fan speed N° 4 4
Sound pressure (hh.-h.-m.-l.) dB(A) 37-34-31-28 38-34-32-30
Liquid pipe diameter mm (inch") 6.35 (1/4") 6.35 (1/4")
Gas pipe diameter mm (inch") 9.52 (3/8") 9.52 (3/8")
Net dimensions (H./W./D.) mm 265x790x170 275x845x180
Net weight Kg 9 10
Technical data
4 indoor unit matchings
378
mm
Less bulk and less energy consumption!
Technical data i.u.