Datasheet

www.argoclima.com
JUNO
DCI
31
e technical data provided refers to European Standard EN14511 - Directive 2002/31/CE
D C I
ON-OFF
Unit of
measurement
JUNO 9 DCI JUNO 12 DCI
COOLING HEATING COOLING HEATING
Capacity nominal (min.-max.)
kW 2,50(0,5-3,2) 2,80(0,8-3,6) 3.50 (0.51-3.90) 3.90 (0.88-4.40)
BTU/h 8530 (1710-10910) 9550 (2730-12280) 11950 (1740-13300) 13300 (3000-15000)
kcal/h 2160 (430-2760) 2410 (690-3100) 3017 (440-3360) 3360 (760-3800)
Energy Label ABCDEFG A A A A
E.E.R. / C.O.P. (kW/kW) 3,24 3,61 3.24 3.61
Air flow rate I.U. (hh.-h.-m.-l.) m³/h 550-500-400-300 600-500-400-300
Dehumidification l/h 0,8 1.4
Fan speed (I.U. / O.U.) 4/1 4/1
Sound pressure I.U. (hh.-h.-m.-l.) dB(A) 40-37-35-32 42-39-36-33
Sound pressure O.U. (high speed) dB(A) 50 52
Electrical power supply V/Ph/Hz 230/1/50 230/1/50
Power input kW 0,77 (0,25-1,36) 0,775 (0,2-1,38) 1.08 (0.23-1.30) 1.08 (0.25-1.45)
Annual energy consumption in cooling mode (500h)-Dir. 2002/31/CE kWh 385 (125-680) - 540 (115-650) -
Compressor type Rotary DC Inverter Rotary
Type of refrigerant R410A R410A
Liquid pipe diameter mm (inch") 6,35(1/4") 6.35 (1/4")
Gas pipe diameter mm (inch") 9,52(3/8") 9.52 (3/8")
Pipe lenght with standard charge m 5 5
Maximum pipe length m 15 20
Maximum height difference (outdoor unit above) m 10 10
Maximum height difference (indoor unit above) m 10 10
Net dimensions I.U. (H./W./D.) mm 265x790x170 275x845x180
Net dimensions O.U. (H./W./D.) mm 540x776x320 540x776x320
Net weight I.U. / O.U. Kg 9/27 11/29
Juno is also available in a DC inverter version, to provide even better
performance and instant and continued comfort with extremely low
energy consumption; in addition, certain technological refinements aim
to reduce power consumption at start-up and improve operation at low
temperatures; all very quietly...
265/
275 mm
790/845 mm
170/180 mm
Technology means comfort!
Technical data