EN LOCAL AIR CONDITIONER OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage. Store these instructions in a safe place for future reference.
GENERAL OPERATING AND SAFETY INSTRUCTIONS • This appliance is a local air conditioner designed for domestic use. • Only use this air conditioner as described in this manual. • Ensure that the required voltage and frequency (220-240 V/50 Hz) match the available power source. • Fuse style T3.15AL AC250V, the electricity passing through the fuse cannot be above 3.15A.
• Do not install the air conditioner in rooms potentially subject to water sprays (e.g. laundries). • This air conditioner can be used by children of 8 years or older and by persons with reduced physical, sensory and mental abilities, or lacking the necessary experience and knowledge, provided they are supervised or instructed on its use by a person responsible for their safety, so that they are fully aware of the attendant risks.
• The air conditioner is fitted with a system to protect the compressor from overload. This means that the compressor only starts 3 minutes after its previous stoppage. • Please wait at least 3 minutes before starting the unit. This helps prevent the compressor from being damaged. WARNING! In the event of an anomaly, switch the appliance off and unplug from the socket. Do not dismantle or attempt to repair or modify the product. In the event of a malfunction, contact the service centre directly.
DESCRIPTION OF THE APPLIANCE FRONT VIEW 1) CONTROL PANEL AND BUTTONS FOR OPERATION WITHOUT REMOTE CONTROL 2) FIN AND AIR FLOW OUTLET 3) FRONT 4) HANDLES 5) AIR INTAKE 6) HANDLES 7) DRAINAGE HOLE (DEHUMIDIFICATION) 8) AIR INTAKE 9) POWER PLUG SOCKET 10) POWER CORD OUTLET 11) DRAINAGE HOLE (COOLING) REAR VIEW 12) UPPER FILTER (BEHIND GRILLE) 13) UPPER AIR INTAKE 14) LOWER FILTER (BEHIND GRILLE) 15) LOWER AIR INTAKE 16) POWER CORD BUCKLE 17) CASTERS 18) REMOTE CONTROL (18) Min/max operati
APPLIANCE START-UP Open the packaging and pull out the box. Remove the product and the other elements supplied (illustrated in the box below). Infrared remote control. + button battery (CR2032/3V) Round fitting (1) for positioning between the air discharge outlet and the flexible pipe. Window unit kit with plug. Round fitting for window unit, for positioning between the end of the tube and the window unit itself. Flexible pipe. End fitting for window (2). Drainage tube (continuous drainage).
3. Connect the end part of the flexible pipe to the round fitting for the window (2). The drainage tube can be compressed to minimum 45 mm and extended to maximum 1500 mm. It is advisable to keep the tube compressed to the minimum. 4. Open the windows and lock one of the two leaves with the handle. Place the end fitting against the fixed leaf of the window and draw the other leaf against it. 5. Avoid tight bends and folds in the flexible pipe. USE WITH WINDOW UNIT KIT 1.
HOW TO USE THE APPLIANCE This appliance can be used for PEARL cooling, dehumidification and ventilation. When switching between modes, the fan continues to turn but the compressor stops: the compressor will re-start after 3 minutes. This delay protects the compressor from potential damage.
HOW TO ELIMINATE CONDENSATE Cooling This appliance automatically vaporises condensate in the cooling and heating mode. Ensure that when the unit is operating in cooling and heating mode, the rubber caps closing the drainage holes on the rear of the appliance are properly positioned. When the air conditioner operates in cooling and heating mode, there is no need for continuous condensate drainage; only in specific weather conditions with very high air humidity levels may water deposit inside the unit.
FOR OPTIMAL REMOTE CONTROL OPERATION, POINT THE TRANSMITTER HEAD TOWARDS THE RECEIVER ON THE AIR CONDITIONER. 2 3 4 SPEED SWING TIMER ON/ OFF 1 SLEEP 5 + DRY COOLFAN 6 - 7 10 9 1. 2. 3. 4. 5. 6. 7. 8. 9. ON/OFF BUTTON SPEED BUTTON SWING BUTTON TIMER BUTTON (LCD ON/OFF) SLEEP BUTTON “+” AND “-“ BUTTON FAN BUTTON COOL BUTTON DRY BUTTON HEAT 8 (1) “ON/OFF” BUTTON Press the ON/OFF button to turn on or off the air conditioner.
(7) “FAN” BUTTON Press “FAN” to start the Ventilation mode. (8) “COOL” BUTTON Press “COOL” to start the refrigeration mode. (9) “DRY” BUTTON Press “DRY” to start the dehumidification mode. Note: Only when temperature reaches 16°C can we turn on the dehumidification mode, besides, the drain pipe must be installed. CARE AND MAINTENANCE WARNING! Before carrying out any cleaning or maintenance operations, unplug the appliance. 1.
4. Transport. Where possible, transport the air conditioner in a vertical position. Should this not be possible, rest it on its right-hand side; when the appliance reaches its final destination, place it immediately in the vertical position and wait at least 4 hours before operating it in cooling mode. 5. For complete safety, regularly check the condition of the power cord; should it be damaged as a result of wear, contact the Service Centre to replace it.