Install Instructions
14
SOURCE POWER, 240V/60HZ/1PH 3-WIRE, BY OTHERS
(SOURCE DU COURANT, 240V/60HZ/1PH 3-FILS, OU AUTRES)
NEUTRAL BLOCK
(BLOC NEUTRE)
WHT/BLK (BLANC/NOIR)
WHT (BLANC)
N
WHT (BLANC)
WHT/BLK (BLANC/NOIR)
WHT (BLANC)
WHT (BLANC)
ELEMENT #4 RELAYS
(RELAIS DE ĽÉLÉMENT No4)
WHT/BLK (BLANC/NOIR)
ELEMENT #4
(ÉLÉMENT No4)
OFF
(FERMÉ)
N
C2
120VAC
CIRC
L
C1
H4
L2
L
N
120VAC
INPUT
(ENTRÉE)
TRANSFORMER
(TRANSFORMATEUR)
H3
L2
L1
H4
CIRC
ON
(OUVERT)
CONTROL
(COMMANDE)
BLK (NOIR)
ARGO "AT" ELECTRIC BOILER
SCHEMATIC WIRING DIAGRAM
4 ELEMENT BOILER,
WITH BREAKERS
13
2
L2
4
L1
ARGO LOAD CENTER
(CENTRE DE CHARGE ARGO)
THERMOSTAT, BY OTHERS
(THERMOSTAT, OU AUTRES)
RED (ROUGE)
T-T
HL
ELEMENT #2 RELAYS
(RELAIS DE ĽÉLÉMENT No2)
ELEMENT #3 RELAYS
(RELAIS DE ĽÉLÉMENT No3)
WHT/BLK (BLANC/NOIR)
ELEMENT #3
(ÉLÉMENT No3)
ELEMENT #2
(ÉLÉMENT No2)
H2
HEATING ELEMENTS
ENERGIZED
(ACTIVATION DES
ÉLÉMENTS DE
CHAUFFAGE)
H3
L1
RED (ROUGE)
H2
L1
FAULT
(DÉFAILLANCE)
4
2
L2
3
1
LWC
FLOW
FLOW
LWC
ELEMENT #1 RELAYS
(RELAIS DE ĽÉLÉMENT No1)
WHT (BLANC)
ELEMENT #1
(ÉLÉMENT No1)
DIFFERENTIAL
(DIFFÉRENTIEL)
H1
L1
SETPOINT
(RÉGLAGE)
20
160
180
170
150
8 16
4
12
H1
100
90
110
130
120
L2
140
TT
TT
HL
RTD
WHT (NOIR)
WHT/BLK (BLANC/NOIR)
WHT (BLANC)
WHT/BLK (BLANC/NOIR)
WHT/BLK (BLANC/NOIR)
WHT (BLANC)
WHT/BLK (BLANC/NOIR)
WHT (BLANC)
RED (ROUGE)
WIRE LEGEND / (LÉGENDE DES FILS)
- DRY CONTACT WIRING (POSE DES CÂBLES DE CONTACT SEC)
- 120 VOLT WIRING (POSE DES CÂBLES 120 VOLT)
- 240 VOLT WIRING (POSE DES CÂBLES 240 VOLT)
- 120 VOLT FIELD WIRING (POSE DES CÂBLES 120 VOLT SUR EN CHANTIER)
- 240 VOLT FIELD WIRING (POSE DES CÂBLES 240 VOLT EN CHANTIER)
(DIAGRAMME SCHÉMATIQUE DU CÂBLAGE
D'UNE CHAUDIÈRE À 4 ÉLÉMENTS)
- DRY CONTACT FIELD WIRING (POSE DES CÂBLES DE CONTACT SEC
EN CHANTIER)
EQUIPMENT GROUNDING LUG
(TENON DE PRISE Á LA TERRE DE Ľ APPAREIL)
OPTIONAL FLOW SWITCH, BY OTHERS
(INTERRUPTEUR DE DÉBIT - FACULTATIF, OU AUTRES)
SOURCE POWER, 120V/60HZ/1PH , BY OTHERS
(SOURCE DU COURANT, 120V/60HZ/1PH, OU AUTRES)
OPTIONAL LWCO, BY OTHERS
(ISPOSITIF D'ARRET EN CAS FAIBLE NIVEAU D'EAU -
FACULTATIF - OU AUTRES)
HIGH LIMIT SAFETY SWITCH, AUTO RESET
(INTERRUPTEUR DE SÉCURITÉ DE LIMITE SUPÉRIEURE,
REMISE EN MARCHE AUTOMATIQUE)
HIGH LIMIT SAFETY SWITCH, AUTO RESET
(INTERRUPTEUR DE SÉCURITÉ DE LIMITE
SUPÉRIEURE, REMISE EN MARCHE AUTOMATIQUE)
FACTORY INSTALLED JUMPERS
(CALVALIERS INSTALLÉES Á ĽUSINE)
RTD WATER TEMPERATURE SENSOR
(CAPTEUR DE LA TEMPÉRATURE DE ĽEAU RTD)
CIRCULATOR PUMP, BY OTHERS
(POMPE DE ĽACCELERTEUR, OU AUTRES)
CIRCULATOR RELAY
(RELAIS DU
ĽACCELERTEUR)
ARGO ELECTRONIC BOILER CONTROL
(COMMANDE ÉLECTRONIQUE DE LA CHAUDIÈRE ARGO)
SAFETY SWITCHES
(INTERRUPTEURS DE SÉCURITÉ)
WIRING DIAGRAMS
FIGURE 8B