Operation Manual
6
EG
AUTOMATIC OPERATION
DEFROSTING OF OUTDOOR UNIT HEAT 
EXCHANGER
When the outdoor temperature is low, frost or ice may 
appear on the heat exchanger coil, reducing the heating 
performance. When this happens, a protection function 
for the heat exchanger defrosting is activated. During this 
function operation, the fan of the indoor unit stops. Heating 
operation restarts after several minutes. (This interval 
will vary slightly depending on the room and outdoor 
temperature).
HEATING PERFORMANCE
A heat pump conditioner heats a room by taking heat 
from outside air. The heating efficiency will fall off when 
the outdoor temperature is very low. If enough heat is not 
obtained with this air conditioner, use another heating 
appliance in conjunction with it.
ONON ON
∆ 1 H ∆  1 H
MIN.MAX.
A
B
C
C
B
A
27
26
25
24
23
22
21
20
19
Example of operation diagram in the (Auto) mode 
with the set room temperature at 23°C.
NOTE
The air conditioner changes the operation mode (from cool 
to heat or vice versa, if one of the following conditions 
occurs:
- ZONE A: changes if the difference between the room 
temperature and the temperature set on the remote 
control unit is at least 3°C..
- ZONE B: changes if the difference between the room 
temperature and the temperature set on the remote 
control unit is at least 1°C, one hour after the compressor 
stop.
- ZONE C: never changes if the difference between the 
room temperature and the temperature set on the remote 
control unit is no more than 1°C.
1. Set the or selector to AUTO (symbol  on the 
display; also the symbol or remains displayed).
2. Press the 
+/- buttons (temperature selection)
 to set the 
desired temperature (the temperature range is between 
32 °C max. and 10 °C min.).
When this setting is selected, the air conditioner will operate 
automatically switching to the COOL or HEAT mode as 
appropriate (regardless of the symbol displayed).
THE DISPLAY SHOWS THE 
SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE 
REQUIRED TEMPERATURE SETTING 
THE DISPLAY WILL SHOW THE ROOM 
TEMPERATURE AGAIN.
3. Press the FAN selector button to the setting you want.
During Automatic Operation (+ IFEEL ON) the set 
temperature is understood as perceived one, then the 
system is automatically adjusted not only according to the 
air temperature, but also based on the relative humidity, 
according to the “humidex” index. 
Verify that the unit is connected to the 
main power and the STANDBY lamp is 
light up.
1. Set the selector to COOL (symbol 
on the display).
2. Press the +/- buttons (temperature 
selection) to set the desired temperature 
(the temperature range is between 32 °C 
max. and 10 °C min.).
HOW TO SET THE PRESENT TIME
HEATING 
1.  Press the button ST three times.
  The time indication alone flashes.
2.  Press the H button until the present time hour is 
displayed. Press the M button until the present time 
minutes are displayed. The display will automatically 
stop flashing.
1. Set the selector to HEAT (fixed or blinking symbol 
on the display.
2.  Press the +/- buttons (temperature selection) to set 
the desired temperature (the temperature range is between 
32 °C max. and 10 °C min.).
THE DISPLAY SHOWS THE 
SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE 
REQUIRED TEMPERATURE SETTING 
THE DISPLAY WILL SHOW THE ROOM 
TEMPERATURE AGAIN.
3. Press the FAN button to select the fan speed.
For several minutes after the start of heating operation, the 
indoor fan will stop until the indoor heat exchanger coil has 
warmed up sufficiently. This is because the COLD DRAFT 
PREVENTION SYSTEM is operating. During this period, 
the STANDBY lamp remains lit.
NOTES
COOLING
THE DISPLAY SHOWS THE 
SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE 
REQUIRED TEMPERATURE SETTING 
THE DISPLAY WILL SHOW THE ROOM 
TEMPERATURE AGAIN.
3. Press the FAN button to select the fan speed.
NOTE
C
1
 3
2
2
1
Generally the fan stops when the set temperature is 
exceeded (when you have selected the fixed HEATING 
symbol ).
HEATING RECIRCULATION FUNCTION
If you want to let the fan run even after the set temperature is 
exceeded, for example, in order to make the heating, coming 
from a nearby source, circulate (eg. fireplace installed under 
the air conditioner), press the selector until the blinking 
HEATING symbol is displayed.