User`s manual

Tracker3 User’s Manual 38
Selects transmission baud rate. Note that the reception baud rate is fixed
at 1200 baud.
Return value: 99 = invalid setting, 0 = 1200, 1 = 300, 2 = PSK31
HEADERLN on|off
Breaks
MONITOR
packets into two lines, with header and payload
separated.
HOPLIMIT <n> <hops>
For digipeater alias <n> (1-8), sets the maximum number of digipeater
hops allowed. This can be used to limit excessively long paths that may
cause network degradation.
INFO
Displays general system and diagnostic data, including number of packets
heard, packets digipeated, and frame check sequence errors detected.
INTERVAL <0-65535> (seconds)
Sets the interval between automatic transmissions.
LVINHIBIT <0-255> (* 0.0784 volts)
Sets the low-voltage inhibit threshold. When the supply voltage drops
below this level, the unit will cease transmitting. Each unit is 0.0784 volts,
so a setting of 100 equals 7.84 volts.
MAXRANGE <0-255> (miles)
When set to a non-zero value, waypoints will only be created for stations
and objects within the specified range.
MONITOR on|off
Displays incoming packets on the console as they are received.
MYCALL <xxxxxx-nn>
Sets the unit's callsign and optional SSID.
NICE <n>
When the tracker hears one of its own packets digipeated, it will skip the
following <n> transmissions. This allows a faster beacon rate to be used in
areas with poor coverage, without increasing the load on the network in
areas with better coverage.