Product specifications
AREXX Engineering & JM3 Engineering
Version: 1.05 Nov. 9
th
, 2014 page: 8
3. Commands / Register
3.1. MS5607-02BA03
Read Command
Hex Code
Reset
0x1E
Convert D1 (OSR=256)
0x40
Convert D1 (OSR=512)
0x42
Convert D1 (OSR=1024)
0x44
Convert D1 (OSR=2048)
0x46
Convert D1 (OSR=4096)
0x48
Convert D2 (OSR=256)
0x50
Convert D2 (OSR=512)
0x52
Convert D2 (OSR=1024)
0x54
Convert D2 (OSR=2048)
0x56
Convert D2 (OSR=4096)
0x58
ADC Read
0x00
PROM Read
0xA0 to 0xAE
Since there are no register on the barometer chip you have to follow the given procedure to read
data after power up:
1. Issue Reset
2. Read PROM (128 bit of calibration words)
3. Initiate pressure (D1) conversion followed by Read ADC result (24 bit)
4. Initiate temperature (D2) conversion followed by Read ADC result (24 bit)
For detailed description of the commands and data processing refer to the datasheet.