User's Guide
ScanBrickĀ® W User Manual
Doc: ARE-016631
Issue: 7.2
Date: Sept 2022
24
State Visualization
The State Panel allows to have a complete description of the state of the application:
- Connection State: it can be CONNECT (radar is currently connected to the application) or
DISCONNECTED (radar disconnected).
- Acquisition State: it can be READY (acquisition not configured yet), CONFIGURED (the
acquisition has been configured at least one time) or ACQUIRING (the system is currently
acquiring data and updating measure results).
- Acquisition Rate: is the frequency of the radar (expressed in Hertz) of acquisition of a new
data. It depends on the selected Acquisition Speed (see Fig.12).
- Acquired: it is the number of acquired data from the start of the acquisition.
- Missed: it is the number of missed data from the start of the acquisition.
- Accumulated: it is the number of accumulated data, i.e. the number of data received and not
processed yet to get a new level measure. If this value increases, this means that the selected
data frequency is too high for the application processing (hence it is suggested to reduce the
Acquisition Speed or to increase the Acquisition Average, see Fig.12).
Fig.14 State Panel
Data Visualization
When the Acquisition State of the application is in ACQUIRING, the measure results are displayed
in the panel of Fig.15. In the upper panel, the grid of measure is displayed: for each point of the (Phi,
Theta)-grid the instantaneous measure of distance is reported.