Installation manual
Arecont Vision MegaBall™ Installation Manual 
5 | Page 
12.  To adjust the camera tilt, pan or z-axis (yaw), 
loosen the 3 set screws on the in-ceiling 
mount as shown in Image 6. Then adjust as 
necessary and retighten the 3 set screws.  
Adjusting the Tilt, Pan, Z-Axis (Yaw): 
  Image 6 
NOTE : The 3 axis in-ceiling camera allows 
360° camera body rotation, 90° tilt, and 360° 
camera sleeve rotation for easy installation in 
any location as shown in Image 7. 
Image 7 
13.  For the vari-focal model, adjust focus, iris and 
field of view using the provided Security L-Key 
(Image 1F) as shown in Image 8.  
Adjusting the Focus, Iris and Field of View: 
  Image 8 
14.  For the fixed-focal model, adjust the focus by 
loosening the two set screws on the front shell 
as shown in Image 9 using the supplied 
double sided hex key (Image 1G). 
 Image 9  Image 10 
15.  Adjust the lens adapter to focus the camera 
as shown in Image 10.  Retighten the set 
screws once focusing is complete.  
Iris 
Focus 
Tilt 90
° 
Set Screw 
Zoom 
Camera Body 
Rotate 360
° 
Camera Sleeve 
Rotate 360
° 