INPUT Alarm Control and Detection 
The input optocoupler supports two ways to connect external unsupervised alarms to Arecont Vision camera. 
Only one of the following two schemes should be used at any given time. 
OPTION-1: UNSUPERVISED ALARM DETECTION 
In this scheme the IN+ & IN- terminals can be used for external signaling devices, such as door contacts or 
motion detectors. Both normally open and normally closed devices are supported as shown below 
IN+ IN- GNDOUT+ OUT-
IN+
IN-
Open / 
Close
The diagram below illustrates the unsupervised alarm conditions: 
IN+ IN- IN+ IN-
IN+
IN-
IN+
IN-
Normally Open Normally Closed
The following table shows how camera detects unsupervised alarms: 
Input Unsupervised Alarms 
Terminals 
External 
Status 
Camera 
Status 
IN+ & IN- 
OPEN 
ON 
CLOSE 
OFF 
Camera status can be read with the following command: 
http://camera_ip/get?auxin 
OPTION-2: INPUT VOLTAGE DETECTION 