Installation Manual
Microdome Duo®    Installation Manual 
Page | 17  support@arecontvision.com 
 +1.818.937.0700 | 877.CAMERA.8 | www.arecontvision.com | avsales@arecontvision.com    
Connecting Digital I/O 
1.  To use digital I/O use 5-wire pigtail cable (included) and plug it into I/O connector (Pic 13). The color 
coding is shown in Table 1 below 
PIC. 20 
5-Pin I/O Connector PoE Connector AC/DC Connector 
Electrical Characteristics 
MIN 
MAX 
PIN 
I/O CABLE WIRE COLOR 
Input Voltage (V) 
(Measured between “+” and “–“ terminals) 
ON 
2.9 
6.3 
3 
WHITE (OUT +) 
OFF 
0 
1.3 
4 
BLACK (OUT -) 
Output Current (mA) 
(Measured between “+” and “–“ terminals)                               
Applied Voltage Range: 0-80V 
ON 
- 
50 
1 
ORANGE (OUT +) 
OFF 
- 
0.1 
2 
YELLOW (OUT -) 
GROUND 
5 
GREEN 
Table 1. 
The output consists of an optically coupled solid state relay (SSR) and the input has an optocoupler. Both the 
SSR and optocoupler have an isolation voltage of 1500 VRMS between the external terminals and internal 
camera circuitry. The input is further protected with a serial 250Ω resistor and a debouncing circuit.  