Installation Manual
Microdome Duo® Installation Manual
Page | 21 support@arecontvision.com
+1.818.937.0700 | 877.CAMERA.8 | www.arecontvision.com | avsales@arecontvision.com
In this scheme the IN- & GND terminals can be tied to an external power source. The camera can detect a
range of voltage to trigger an internal alarm on|off condition.
IN+ IN- GNDOUT+ OUT-
0-12VDC
50mA
(max)
+
-
The following table shows the input voltage range and electrical characteristics:
Input Voltage Detection
Terminals
External
Status
Camera
Status
Voltage
Range
Current
Range
IN- &
GND
OFF
ON
0-1V
0-2mA
ON
OFF
2-12V
10-50mA
The status of the camera can be read with the following command:
http://camera_ip/get?auxin