Installation Manual
    Installation Manual 
Page | 10 support@arecontvision.com 
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com 
MegaVideo® Flex 
Mounting the Main Unit 
1.  Determine a secure location to mount the main unit from the camera. There is a 40ft. maximum 
distance from the camera to the main unit.  
Mount Procedure for Drywall/Masonry   Mount Procedure for Metal Application 
Ref # 
Description  
For Drywall/ Masonry Applications 
1 
Prepare surface for installation by placing the main unit where desired and marking each of 
the four the holes with a pencil. 
2 
Drill the appropriate size holes to install 4x of the #6-32 1” Drywall/ Masonry Mounting 
Anchors (Ref #2) where you marked the pencil holes. 
3 
Place the holes of the main unit over the Drywall Mounting Anchors and use a Philips head 
screwdriver to screw 4x of the #6-32 1.5” Wood/ Metal Sheet Screws (Ref #3). 
For Metal/Wood Sheet Applications 
4 
Prepare surface for installation. Then, insert the 4x #6-32 1.5” Machine Screws (Ref #4) 
through the each of the four holes on the main unit.  
5 / 6 
Thread a #6-32 Washer (Ref #5) into each Machine Screw and then fasten securely with a 