6.4 Enhanced VMD System
In Control Center V8.4, live views pop up on the VMD window upon motions only. In Control
Center V8.5, live view can also pop up on the VMD window when the critical temperature is
reached or exceeded.
You can set up a critical temperature upon or beyond which the live view will pop up on the
VMD window for easy monitoring. This feature is only supported by GV-System with GV-3008
Card and most GV-IP Cameras.
Note: For the GV-IP Cameras that support temperature detection, please refer to the
GV-IPCAM H.264 User’s Manual for detail.
1. Add the desired cameras to the VMD Group by dragging them from the Host List.
2. To enable pop-up live view by critical temperature, right-click the camera under the VMD
Group, select Video Analysis and select Temperature Alarm.
3. Click the VMD System icon
. The VMD window appears.
4. On the VMD window, click the Show System Menu icon
on the top right corner and
select System Configure. The System Configure dialog box appears.
5. Type the critical temperature.
Figure 6-18
6. The live view should pop up on the VMD window when the camera’s temperature reaches
or exceeds the specified critical temperature.