MegaVideo
®
 Compact Camera I/O Cable Connection 
Required Tools: 
 Flathead screwdriver 
Image 14 
1.  To use the I/O ports of the MegaVideo
®
Compact Camera, insert the connector into the 
camera and locate the “I/O” ports as shown in 
Image 14. NOTE: There are six connectors 
that look identical, be sure to use the correct 
I/O ports as shown in Image 15. 
Image 15 
Electrical Characteristics:  Min  Max 
Input voltage (V)  ON  2.9  6.3 
(measured between + and – 
terminals) 
OFF 0  1.3 
Output current (mA) 
ON -  50 
(measured between + and – terminals) 
Applied Voltage Rage: 0 - 80V 
OFF -  0.1 
Table 1 
NOTE: Both the input and the output are electrically 
isolated from the rest of the camera’s electrical 
circuitry via general-purpose photo couplers. The 
input is additionally protected with a serial 250 Ohm 
resistor and a debouncing circuit. Duration of any 
input signal should be at least 5ms to comply with 
the requirements of the debouncing circuit. 