DigitalInputandOutput
Use4positionconnectorprovidedin boxtointerfacewithDigitalI/Ooncamerahousing.
ElectricalCharacteristics
MIN MAX
InputVoltage(V)
(Measuredbetween+
and–terminals)
ON 2.9 6.3
OFF 0 1.3
OutputCurrent(mA)
(Measuredbetween+
and–terminals)
AppliedVoltageRange:
0‐80V
ON‐ 50
OFF‐ 0.1
NOTE:Boththeinputandtheoutputareelectricallyisolatedfromtherestofthecamera’selectrical
circuitryviageneral‐purposephotocouplers.Theinputisadditionallyprotectedwithaserial250Ohm
resistorandadebouncingcircuit.Durationofanyinputsignalshouldbeatleast5mstocomplywith
the
requirementsofthedebouncingcircuit.
Output Input