Optional: Connecting Digital I/O
To use digital I/O, connect digital I/O with pigtail cable connector on the main unit.
Reference #
Description
1
Input
2
Output
NOTE: Camera supports digital input and digital output. See Table 1 for electrical characteristics.
Electrical Characteristics
MIN
MAX
Input Voltage (V)
(Measured between +
and – terminals)
ON
2.9
6.3
OFF
0
1.3
Output Current (mA)
(Measured between +
and – terminals)
Applied Voltage
Range: 0-80V
ON
-
50
OFF
-
0.1
Table 1
NOTE: The digital input is electrically isolated from the rest of the camera’s electrical circuitry via
general-purpose photo couplers. The input is additionally protected with a serial 250 Ohm resistor, and
a de-bouncing circuit. Duration of any input signal should be at least 5 ms to comply with the
requirements of the de-bouncing circuit.