Installation Manual

!! ! Installation!Manual!
Page | 14 support@arecontvision.com
!
!
!
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MicroDome®!G2
Optional: Connecting Digital I/O
To use digital I/O, connect digital I/O with pigtail cable connector as shown below.
Reference #
Description
1
Input (White + / Black -)
2
Output (Orange + / Yellow -)
NOTE: MicroDome
®
G2 supports digital input and digital output. See Table 1 for electrical
characteristics.
Electrical Characteristics
MAX
Input Voltage (V)
(Measured between +
and terminals)
6.3
1.3!
Output Current (mA)
(Measured between +
and – terminals)
Applied Voltage
Range: 0-80V
50!
0.1!
Table&1&
!
NOTE: The digital input is electrically isolated from the rest of the camera’s electrical circuitry via
general-purpose photo couplers. The input is additionally protected with a serial 250 Ohm resistor, and
a de-bouncing circuit. Duration of any input signal should be at least 5 ms to comply with the
requirements of the de-bouncing circuit.