Installation Manual
    Installation Manual 
Page | 13 support@arecontvision.com 
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com 
MegaVideo® Flex 
Optional: Connecting Digital I/O 
To use digital I/O, connect digital I/O with pigtail cable connector on the main unit.  
Reference # 
Description  
1 
Input 
2 
Output 
NOTE: Camera supports digital input and digital output. See Table 1 for electrical characteristics. 
Electrical Characteristics 
MIN 
MAX 
Input Voltage (V) 
(Measured between + 
and – terminals) 
ON 
2.9 
6.3 
OFF 
0 
1.3 
Output Current (mA) 
(Measured between + 
and – terminals) 
Applied Voltage 
Range: 0-80V 
ON 
- 
50 
OFF 
- 
0.1 
Table 1 
NOTE: The digital input is electrically isolated from the rest of the camera’s electrical circuitry via 
general-purpose photo couplers. The input is additionally protected with a serial 250 Ohm resistor, and 
a de-bouncing circuit. Duration of any input signal should be at least 5 ms to comply with the 
requirements of the de-bouncing circuit. 