User manual

HARDWARE INSTALLATION
38
Step 7. Re-check the SATA HDD LED and Fault LED Cable
Connections
Be sure that the proper failed drive channel information is dis-
played by the fault and HDD activity LEDs. An improper connection
will tell the user to ‘‘Hot Swap’’ the wrong drive. This will remove
the wrong disk (one that is functioning properly) from the control-
ler. This can result in failure and loss of system data.
Step 8. Power up the System
Check the installation thoroughly, reinstall the computer cover, and
reconnect the power cord cables. Turn on the power switch at the
rear of the computer (if equipped) and then press the power button
at the front of the host computer.
Step 9. Congure Volume Set
The SATA RAID controller congures RAID functionality through the
McBIOS RAID manager. Please refer to Chapter 3, McBIOS RAID
manager, for the detail regarding conguration. The RAID controller
can also be congured through the McRAID storage manager soft-
ware utility with ArcHttp proxy server installed through on-board
LAN port or LCD module. For this option, please refer to Chapter 6,
Web Browser-Based Conguration or LCD Conguration Menu.
Step 10. Install the Controller Driver
For a new system:
• Driver installation usually takes places as part of operating sys-
tem installation. Please refer to Chapter 4 Diver Installation for the
detail installation procedure.
In an existing system:
• Install the controller driver into the existing operating system.
Please refer to the Chapter 4, Driver Installation, for the detailed
installation procedure.