User manual

WEB BROWSER-BASED CONFIGURATION
122
6.7 Physical Drive
Choose this option to select a physical disk from the main menu
and then perform the operations listed below.
6.7.1 Create Pass Through Disk
To create pass through disk, move the mouse cursor to the main
menu and click on the “Create Pass Through” link. The “Select the
IDE Drive For Pass Through” screen appears. A pass through disk
is not controlled by the SATA RAID controller rmware, it cannot
be a part of a volume set. The disk is available to the operat-
ing system as an individual disk. It is typically used on a system
where the operating system is on a disk not controlled by the
RAID rmware. The user can also select the Cache Mode, Tagged
Command Queuing, SCSI channel/SCSI_ID/SCSI_LUN for this
pass through disk.
6.6.5 Stop VolumeSet Check
Use this option to stop the “Check Volume Set function”.