User manual
BIOS CONFIGURATION
73
Multiples Of 10G: If you have 120 GB drives from differ-
ent vendors; chances are that the capacity varies slightly. For
example, one drive might be 123.5 GB, and the other 120 GB.
Areca drive Truncation mode Multiples Of 10G uses the same
capacity for both of these drives so that one could replace the
other.
Multiples Of 1G: If you have 123 GB drives from different ven-
dors; chances are that the capacity varies slightly. For example,
one drive might be 123.5 GB, and the other 123.4 GB. Areca
drive Truncation mode Multiples Of 1G uses the same capacity
for both of these drives so that one could replace the other.
No Truncation: It does not truncate the capacity.Within the
subsystem, the SCSI chip acts as a target and 5 SATA ll bus are
connected to the drive.
3.7.5.9 Controller Fan Detection
We have added, in the product box, a field replaceable passive
heatsink to be used if there is enough airflow to carry out the
heat in the passive heat sink.
The “Controller Fan Detection” function is available in the ver-
sion 1.36 date: 2005-05-19 for preventing the Buzzer warning.
Please disable the “Controller Fan Detection” function through
the BIOS setting.
You can follow the following procedure to disable the Polling
function. (This function is not available in the Web Brows-
er setting.)