6.9.2 Ethernet Configuration (12/16/24 ports)
Use this feature to set the controller Ethernet port configuration.
Customer doesn’t need to create a reserved space on the arrays
before the Ethernet port and HTTP service working. The firmware-
embedded Web Browser-based RAID manager can access it from
any standard internet browser or from any host computer either
User can set the “Disk Write Cache Mode” to: Auto, Enabled or
Disabled.
• Disk Capacity Truncation Mode:
ARECA RAID controllers use drive truncation so that drives from
differing vendors are more likely to be able to be used as spares
for each other. Drive truncation slightly decreases the usable
capacity of a drive that is used in redundant units.
The controller provides three truncation modes in the system
configuration: Multiples Of 10G, Multiples Of 1G, and No
Truncation.
Multiples Of 10G: If you have 120 GB drives from different
vendors; chances are that the capacity varies slightly. For exam-
ple, one drive might be 123.5 GB, and the other 120 GB. Areca
drive Truncation mode Multiples Of 10G uses the same capac-
ity for both of these drives so that one could replace the other.
Multiples Of 1G: If you have 123 GB drives from different ven-
dors; chances are that the capacity varies slightly. For example,
one drive might be 123.5 GB, and the other 123.4 GB. Areca
drive Truncation mode Multiples Of 1G uses the same capacity
for both of these drives so that one could replace the other.
No Truncation: It does not truncate the capacity.