Datasheet

Table Of Contents
IMX219PQH5-C
80
To in power-off sequence varies depending on the CCI communication end timing as shown below.
1. When the CCI communication is performed with Software Standby between SOF and EOF, all communicated
frame data is output and the status is converted to Software Standby.
Fig. 41 Software Standby Operation Pattern 1
2. When the CCI communication is performed with Software Standby during FrameBlanking, the status is
converted to Software Standby immediately after communication.
Fig. 42 Software Standby Operation Pattern 2
S
O
F
E
O
F
N 0xFF
SDA
SCL
CSI2
DATA
Frame
Counter
Enter
Stop
Frame_length_lines
Frame
Blanking
S
O
F
E
O
F
N 0xFF
SDA
SCL
CSI2
DATA
Frame
Counter
Enter
Stop
Frame_length_lines