Datasheet

Table Of Contents
IMX219PQH5-C
49
4-1-4 Data type
Data types of each line are shown as below.
Table 13 Image pixel area and data type
image pixel area
Data Type
Embedded Data Lines
Embedded Data
OBside ineffective area
Null
OB area for internal use
Null
effective OB
OPB Data
Effective area side ineffective area
Null
effective pixel
RAW10 or RAW8 or COMP8
4-1-5 CSI-2 Frame Format
The data format of each line is based on CSI-2 General Frame Format.
The period from a line end sync code to the line start sync code for the next line is called the line blanking period.
Likewise, the period from a frame end sync code to the next frame start sync code is called the frame blanking
period. Packet header consists of the following data.
Table 14 Sync Code Settings
Header
[7:0]
Description
Setting register
Remarks
[7:6]
Virtual Channel Identifier
Addr: 0x0110
See Register Section
CSI_channel_identifier
[5:0]
Synch Short Packet Data types
NA

Frame Start Code
NA

Frame End Code
NA

Embedded Data
NA
Written data in the sensor
A
RAW8
CSI_data_format
0808
B
RAW10
CSI_data_format
A0A