Datasheet

Table Of Contents
Confidential for truly Only
11.03.2009 PRELIMINARY SPECIFICATION proprietary to OmniVision Technologies
4-15
4.9.1 LED1 & 2 mode
Two frames after the strobe request is submitted, the third frame is correctly exposed. The strobe pulse will be activated
only one time if the strobe end request is set correctly (see
figure 4-10). If end request is not sent, the strobe signal is
activated intermittently until the strobe end request is set (see figure 4-11). The number of skipped frames is
programmable using registers {0x3A1C, 0x3A1D}.
figure 4-10 LED 1 & 2 mode - one pulse output
vertical
blanking
exposure
time
data
out
strobe
request
strobe
pulse
correctly
exposed
frame
the number of skipped frames
is programmable
request here
start end
frame in is skipped
5647_DS_4_10