Data Sheet

10.13.2009 PRODUCT SPECIFICATION proprietary to OmniVision Technologies
8-1
8 operating specifications
8.1 absolute maximum ratings
8.2 functional temperature
table 8-1 absolute maximum ratings
parameter absolute maximum rating
a
a. exceeding the absolute maximum ratings shown above invalidates all AC and DC electrical specifications and may
result in permanent damage to the device. Exposure to absolute maximum rated conditions for extended periods
may affect device reliability.
ambient storage temperature -40°C to +95°C
supply voltage (with respect to ground)
V
DD-A
4.5V
V
DD-IO
4.5V
electro-static discharge (ESD)
human body model 2000V
machine model 200V
all input/output voltages (with respect to ground) -0.3V to V
DD-IO
+ 1V
I/O current on any input or output pin +
200 mA
peak solder temperature (10 second dwell time) 245°C
table 8-2 functional temperature
parameter range
operating temperature range
a
a. sensor functions but image quality may be noticeably different at temperatures outside of stable image range
-30°C to +70°C
stable image temperature range
b
b. image quality remains stable throughout this temperature range
0°C to 50°C