manual
We do the utmost to ensure that the provided informaon is complete and accurate; however, images and
specicaons are subject to change without noce. Visit our website at www.ardaappliances.com
for the latest version of this manual.
- 5 -
1. Arda hoods exhaust vercally up through the ceiling to the roof
(Fig. 3). They can be ducted to the rear behind the decorave
chimney duct through an outside wall.
2. Plan where the ductwork will run between the hood and the
outside.
3. A short straight duct run will produce the most air ow. Longer
lengths and elbow ducts will reduce the eciency of the blower.
4. Install a roof or wall cap outside your home. Connect a 6” round
metal duct to the cap and work backwards towards the hood. Ensure
connecons are completely sealed with duct tape.
5.
1. Decide on the mounng height of the hood (C - Fig. 2). You will need to consider the following:
In general the minimum mounng height above an electric
range is 24” and above a gas range is 30”. Check your range’s
installaon manual for the correct minimum mounng height
for your installaon.
Mounng the hood at a height where the
controls are at eye level is usually most convenient.
actors such as symmetry and alignment within your
backsplash and/or cabinetry.
of the decorave chimney.
2. Mark the mounng height (C) on the plumb line (B).
3. The mounng holes on the hood are used for aaching the
hood to the wall. Measure the distance between the boom of the hood and the top of the
mounng holes on the hood (D - Fig. 5). Draw a line perpendicular to the center/plumb line (B)
at this height. Measure the distance between the
mounng holes on the hood (E). Center and mark this
measurement on line D. Ensure that this measurement
is centered on either side of the center (plumb) line.
This is where the mounng holes are to be posioned.
4. Behind the drywall and any backsplash material, in-
stall cross-bracing between the wall joists at the level
of the mounng screw holes (Fig. 4)
5. Insert the mounng screws through the marked
mounng holes, leaving about 1/4” of the thread
exposed. Ensure you use the appropriate type of
screws for your wall/crossbracing.
!
Hood
Roof Cap
Wall Cap
Duct
Fig. 3
Fig. 4
Center line
Mounng Holes
Drywall
Framing
Wood
cross-
bracing
Fig. 5
Mounng Holes
E
Oset
Height
D
Center (Plumb)
Line
B
Mounng Height
(to cooktop)
C